Kaba Mas LA GARD BASIC 3802 Manager Instructions

Kaba Mas LA GARD BASIC 3802 Manager Instructions

Firmware dual-handed swing bolt lock or dead bolt

Advertisement

Quick Links

LOCKS:
Dual-handed
Dead Bolt Lock
Swing Bolt Lock
• 8 Digit code – default code 5-5-5-5-5-5-5-5 [consistent with other LA GARD locks]
• If the default code is not changed before Manager changes his or her code then the SMR option will be lost, unless hard reset of the lock
is performed.
• Once set the SMR cannot be changed, unless hard reset.

FACTORY RESET PROCEDURE

Remove Battery.
• Hold down key "0" for 10 seconds to discharge all internal capacitors.
• Connect Reset Box (p/n 6066) to alarm box connector. Put the battery back in place, factory reset is completed.
Disconnect Reset Box.
• Lock configuration is: only manager code exists, set to 1-2-3-4-5-6. Audit file not cleared.
• Lock is operational with manager code only; other users are deleted.

LOCK USERS

Manager
• Open Lock
• Change Combination
• Enable/Disable User
• Delete User
Users
• Open Lock
• Change Combination

STANDARD LOCK FEATURES

Wrong Try Penalty
• Entry of four (4) consecutive invalid combinations initiates a five (5) minute delay penalty. Lock responses during the penalty period are
as follows:
- The LED will flash every ten (10) seconds. If any key is pressed, there is no response.
• Once the penalty period has ended, two (2) consecutive invalid combinations will initiate another five (5) minute penalty period.
Low Battery Warning
• Repeated audio/visual signals (LED flashes/beeps) during Lock opening indicate the battery is low and should be replaced immediately.
• If the battery level becomes too low to safely operate the Lock, pressing any key will initiate the low battery warning. The battery must be
replaced before the Lock will operate.

LOCK OPERATING CONVENTIONS

• If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation.
• To access lock commands, enter combination and hold down the last digit until Lock double signals and the LED stays on.

LOCK RESPONSES

Standard Operations
• Manager Menu – LED on during operation
• Double signal - two (2) LED flashes and two (2) beeps indicate entry is valid or accepted.
• Triple signal - three (3) LED flashes and three (3) beeps indicate invalid or not accepted.
• Lock must be opened within 4 seconds once a valid combination has been entered.
• To open a container with a Swing Bolt Lock, turn the container handle to the open position and open the door.
• To open a container with a Dead Bolt Lock, turn the keypad or dial to retract the bolt and open the door.
• When closing a container, verify that it has been secured.
(P/N) 760.128 Rev G 12/13 • © copyright 2004-2013
BASIC SERIES
3802 Firmware Dual-Handed Swing Bolt Lock or Dead Bolt
MANAGER INSTRUCTIONS
3000 Entry
3710 Entry
(Swing Bolt Only)
(Swing Bolt Only)
KEYPADS:
3035 Entry
3715 Entry
(Swing Bolt Only)
3750 Entry
3190 Privat
II
(Optional)
Kaba Mas LLC
Page 1 of 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LA GARD BASIC 3802 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kaba Mas LA GARD BASIC 3802

  • Page 1 • To open a container with a Dead Bolt Lock, turn the keypad or dial to retract the bolt and open the door. • When closing a container, verify that it has been secured. (P/N) 760.128 Rev G 12/13 • © copyright 2004-2013 Kaba Mas LLC Page 1 of 2...
  • Page 2 NOTE: The Input Unit 3190, audit features, the software features associated with peripheral devices and systems, the silent alarm feature, and other additional features have not been evaluated by UL. (P/N) 760.128 Rev G 12/13 • © copyright 2004-2013 Kaba Mas LLC Page 2 of 2...

Table of Contents