RANGE

You can't adjust the range when the X-28 is in
the automatic mode. It is adjustable when the
unit is in the manual mode, however. To do
so, first put the unit in the manual mode. Now
press a menu key until the "RANGE SEL"
menu appears as shown at right. The current
range shows at the bottom of the menu. In this
case, the range is 60 feet. Now press the up
arrow key to decrease the range, the down
arrow key increases the range. After you
select the desired range, press the PWR/
CLEAR key to clear the display. If you wait a
few seconds, it automatically clears.
The X-28 has the following ranges:
10, 20, 40, 60, 120, 240, 480, and 900 feet.
and
5, 10, 20, 40, 60, 100, 200, and 300 meters.
NOTE: The depth capability of the X-28 depends on the transducer
installation, water and bottom conditions, and other factors.

RANGE - Upper and Lower Limits

The X-28 lets you change the upper and lower range limits when it's in the
manual mode. This lets you "zoom" in on segments of the water as small
as 10 feet. In other words, you can set the upper limit to 25 feet and the
lower limit to 35 feet, regardless of the bottom
depth. This in essence, gives you a 10 foot
zoom. You can choose any segment of the
water, as long as the distance between the
upper limit and lower limit is 10 feet (10
meters) or more.
To change the upper limit, first make certain
the unit is in the manual mode. Next, press a
menu key until the "UPPER LIMIT" menu
appears. Now press the down arrow key to
increase the upper limit or the up arrow key to
increase it. After you've finished, wait a few
6