FREQUENTLY ASKED QUESTIONS FOR WIRELESS SECURITY SYSTEM WA410/ SY4100
1) Q: This WA410/ SY4100 system compatible with WA400/ SY4000 system?
A: No, this is due to the different communication method use between the main console and
peripheral units with WA410/ SY4100 System and WA400/ SY4100 System so there is no
compatibility between these systems including the peripheral units.
2) Q: Can this system be monitor by the security monitoring company?
A: No, this system is stand alone type and there is no capability to communicate with the security
monitoring company.
3) Q: Can the emergency, police/ fire department telephone number be programmed in to
the system?
A: Please check the local authorities that to ensure "Auto Dialer" security features are permissible
with that particular local area and that the telephone numbers which you will program are correct.
4) Q: What is "Away/ Home" arm mode?
A: Away arm mode: When the system is armed in this mode, all sensors are active and the any
of sensor is triggered, the system will activate the alarm as well as the auto dialer function.
Home arm mode: When the system is armed in this mode, all PIR sensor zones are excluded
from the system and the activation of these sensor will not activate the alarm neither the auto
dialer function.
5) Q: What is "Instant/ Delay/ Home Bypass/ 24 Hr zone?
A: Instant Zone: This zone is belong to the "Window Sensor" and if the system is in arm mode,
the alarm/ auto dialer function will activate immediately when the sensor belong to this zone is
triggered.
Delay Zone: This zone is belong to "Door/ PIR Motion Sensor" and if the system is in arm mode,
the alarm/ auto dialer function will activate after the entry delay period when the sensor belong to
this zone is triggered.
Home Bypass Zone: This zone is belong to "PIR Motion Sensor" and if the system is in "Home
Arm Mode", the alarm/ auto dialer function will not activate when the sensor belong to this zone is
triggered and the sensor belong to this zone will be excluded from the system.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WA410 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lorex WA410

  • Page 1 1) Q: This WA410/ SY4100 system compatible with WA400/ SY4000 system? A: No, this is due to the different communication method use between the main console and peripheral units with WA410/ SY4100 System and WA400/ SY4100 System so there is no compatibility between these systems including the peripheral units.
  • Page 2 24Hr Zone: This zone is belong to “Smoke Detector/ Gas Detector/ Panic Watch and Remote Control Panic Button” and if the system is in arm/ disarm mode, the alarm/ auto dialer function will activate immediately when the sensor belong to this zone is triggered. 6) Q: Can the alarm/ exit delay/ entry delay duration be changed? A: Yes, these durations are programmable via the setup menu and can be set individually for duration of 1~255 Sec.
  • Page 3 11) Q: How many voice massages can be programmed with this system for different occasion? A: Unfortunately this system can support only one voice massage for length of 25 Sec maximum. So the content of message must be general. 12) Q: The system produces 2 short trip every 10 Sec after the system is disarmed. How to stop this 2 short trip? A: In any occasion, if you hear 2 short trips every 10 Sec, please check the LCD screen on the main console, there should be the message.
  • Page 4 A: Generally, the battery on the sensor will last for about 6 month but it depends on the frequency of sensor activation. Please keep in mind that the sensors are always “On” regardless of the system status (Arm/ Disarm) and it will transmit signal whenever it is triggered. 17) 17) Q: How many telephone number will dial out and how when the auto dialer function is activated? A: The basically auto dialer will dial out 4 preset telephone numbers (If all preset numbers are...
  • Page 5 20) Q: After programming the “Door/ Window Sensor” to “Door Sensor”. Can this sensor convert to the “Window Sensor”? A: Unfortunately “No”, you can not change the peripheral unit type for already programmed zone. Unless erase all programmed peripheral units from the system and then reprogram all peripheral units again to properly change the peripheral unit type of particular peripheral unit in this case “Door Sensor to Window Sensor”.

This manual is also suitable for:

Sy4100

Table of Contents