Commands and meter data
Data Item
Date and Time stamp
Electricity Meter Status flags
Message ID
MPAN/Customer #
Meter Serial Number
Credit Mode
Emergency credit flags
Present Balance Register
Arrears Register
Rate 1 kWh register
Rate 2 kWh register
E470 Tokenless Smart Prepayment Meter
Issue: 1.8
Clear credit transaction log.
Option to open/close meters contactor. (shows OFF display
second CoT/S command to close contactor).
Option to Zero PPU tariff plan.
Option to reset Billing Period.
Zero Standing Charges.
Zero total credit.
Zero total payments.
Option to clear any future tariffs.
Clear Profile data log.
The CoT/S command will trigger a Snapshot of readings. The returned data
includes data required for prepayment or credit operation and consists of:
Returned in1
H
H
P
P
P
P
P
P
P
P
P
1 Returned In' column denotes whether the item is returned in the message
header (H) or as part of the message payload.
2 Meter status information includes flags to indicate fault conditions/status
of the electricity meter.
Flags will indicate the following:
Watchdog Error
Real Time Clock Error
FRAM (memory) error
Program download active
Meter in Emergency mode
Details
See2 below
Message ID = COTS
Denotes credit or prepayment operating mode
Denotes emergency credit taken or not
Reverse energy detected
SIM card flap tamper
SIM carriage detected
Fingerprint stats error
Fingerprint other error