Spreader And Looper Cam Adjustment; Loopers Adjustment - AMF S-100 Parts And Service Manual

Electronic eyelet buttonhole machine
Hide thumbs Also See for S-100:
Table of Contents

Advertisement

S-311
E
10. S P R E A D E R A N D L O O P E R C A M A D J U S T M E N T
Locate the cam – on the holder gauge
line — when the needle bar is in the
lowest position according to the sec-
tion E3, point 2. To turn a cam,
loosen the screw ˜.
11. L O O P E R S A D J U S T M E N T
11.1. To perform this adjustment,
remove the plates and holder
by loosening the screw
11.2. After the loosening the bracket
screws š, locate left looper › on the axis of the needle œ. By turning the handwheel, raise the needle
bar from the lowest position, to insert a gauge ™
by its higher end between gauge support and the needle
bar end.
11.3. After loosening the screw  adjust the distance
0.1 - 0.2 mm between the needle and looper tip ›.
Tighten the screw again.
11.4. Adjust the same space on the right looper ž when it
passes the needle. To perform it, turn the hand wheel.
11.5. It is important to check the looper distance, according
to the point 11.3. Different distance is necessary to
adjust by turning the needle bar after loosing the screw
22
of the wheel
23
11.6. The correct distance between the loopers and needle has
to be checked in 4 positions of needle bar
plus race. Please see the drawing above.
11.6.
1-52
- STANDARD MACHINE ADJUSTMENT
.
.
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service); +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
Gauge
RYSKA
line
2
3
1
Revised 06/2007