[ Model ] Ceiling Suspended Type
Applicable models
AXHP36AVD
AXHP71AVD
AXHP112AVD
Important reminder
- THOROUGHLY READ THESE INSTRUCTIONS BEFORE STARTING THE INSTALLATION AND FOLLOW
ALL PROCEDURES DESCRIBED WITHIN.
- KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
After installation, always use the checklist to perform a final inspection.
Always read before installation.
Aisin INDOOR UNITS
OPERATION MANUAL
AXHP36 - 112AVD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AXJP22A2D and is the answer not in the manual?

Questions and answers

Summary of Contents for Aisin AXJP22A2D

  • Page 1 AXHP36 - 112AVD Always read before installation. Aisin INDOOR UNITS OPERATION MANUAL [ Model ] Ceiling Suspended Type Applicable models AXHP36AVD AXHP71AVD AXHP112AVD Important reminder - THOROUGHLY READ THESE INSTRUCTIONS BEFORE STARTING THE INSTALLATION AND FOLLOW ALL PROCEDURES DESCRIBED WITHIN.
  • Page 2: Ec Declaration Of Conformity

    AXSP90P7D AXSP112P7D AXSP140P7D AXHP36AVD AXHP71AVD AXHP112AVD AXDP22P7D AXDP28P7D AISIN SEIKI CO.LTD Brand: Marca: See the number on the unit label Serial number: N° di serie: vedere il numero sulla targa dati Year of production: See the year on the unit label...
  • Page 3 1. SAFETY PRECAUTIONS....... 1 2. WHAT TO DO BEFORE OPERATION...3 3. OPERATION RANGE........5 4. INSTALLATION SITE ........5 5. OPERATION PROCEDURE......6 It may result in injury or electric shocks. 6. OPERATION CHARACTERISTICS....6 7. OPTIMUM OPERATION......... 8 8. MAINTENANCE (FOR SERVICE PERSONNEL)...... 9 9.
  • Page 4 Using the air conditioner in such places may cause a fire or air conditioner failures. Accidental operation by a child may result in injury or elec- tric shocks. If the air conditioner is not operating correctly, i.e. not gen- erating cool or warm air, refrigerant leakage could be the cause.
  • Page 5: Printed Circuit Board

    Measuring points for the residual voltage Under certain conditions, condensation on the unit or refrig- A1P X1M erant piping, air filter dirt or drain blockage may cause drip- ping, resulting in fouling or failure of the object concerned. Printed Control Circuit Board After power failure, operation will restart auto-...
  • Page 6 ature sensor to individually control the tempera- ture according to the set temperature on the remote controller. Two remote controllers control one indoor unit (In case of group control system, one group of indoor units). The unit is individually operated. Contact your local dealer in case of changing the combination or setting of group control and two remote controller control systems.
  • Page 7 a. Filled with much mineral oil such as cutting oil b. Where there is much salt such as a beach area c. Where sulfured gas exists such as a hot-spring resort d. Where there are considerable voltage fluctua- tions such as a factory or plant e.
  • Page 8: Heating Operation

     Operating procedure varies with heat pump type and cooling only type. Contact your local dealer to confirm your system type. It generally takes a longer time for indoor temper- To protect the air conditioner, turn on the main ature of the HEATING OPERATION to reach the power switch 6 hours before operation.
  • Page 9 The heating capacity of the air conditioner There are 2 ways of adjusting the airflow direction. declines as the outside air temperature falls. In (When the operation stops, the horizontal blades such a case, use the air conditioner in combina- at the air outlet (Up and down direction adjust- tion with other heating systems.
  • Page 10: Defrost Operation

    For the following conditions, micro computer con- The left and right airflow direction can be fixed at trols the airflow direction so it may be different from the desired position manually. the display. Only make adjustments after you have fixed the COOLING HEATING up and down airflow direction in a position.
  • Page 11: Operation

    Turn off the power circuit breaker when it is not in use for a long period. When the power circuit breaker is turned on, small amount of power is consumed even if the air conditioner is not in oper- ation. (*1) Turn off the power circuit breaker for saving energy.
  • Page 12 Slide the knob to the arrow direction and slowly open the grille. Knob After the air filter is cleaned, return the air filter to the original place as it was attached before. Knobs Slide all the knobs in the reverse order men- AXHP 36 : 2 places tioned in the Clause 1 and securely fix the grille.
  • Page 13 Keep holding the clips at the upper part of the suction grille and pull them to frontward. Slide all the knobs in the reverse order men- tioned in the Clause 1 and securely fix them. Wipe them with a dry soft cloth. Clip When the stain cannot be wiped off, dip the cloth in the neutral detergent diluted with water and...
  • Page 14 Some models perform the following operation to protect the devices. If the HEATING OPERATION is performed within 6 hours after the power is supplied to the air con- ditioner, the indoor fan stops for about 10 minutes during the outdoor unit operation to protect the devices.
  • Page 16 04.2014...