Skope PG Series User Manual

Skope PG Series User Manual

1-1 and 2-1 chillers and freezers
Hide thumbs Also See for PG Series:

Advertisement

Quick Links

SKOPE PEGASUS
PG Horizontal Series
1-1 and 2-1 Chillers and Freezers
PG200HC
PG500Prep
PG800Pizza

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PG Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Skope PG Series

  • Page 1 SKOPE PEGASUS PG Horizontal Series 1-1 and 2-1 Chillers and Freezers PG200HC PG500Prep PG800Pizza...
  • Page 2 For pricing information on an extended warranty visit www.skope.com/warrantyprotection Service & Support We know you will get years of satisfaction from your new SKOPE product when you follow a few simple preventative maintenance guidelines.
  • Page 3: Table Of Contents

    Variations ......... . . 16 SKOPE CAREL S4 EVO ........16 Overview .
  • Page 4 Troubleshooting ........31 SKOPE Pegasus Horizontal Series...
  • Page 5: Models

    SKOPE Pegasus Horizontal Series 1 Models Undercounter Table 1: Undercounter specifications Operating temperature Model Part No. Configuration Doors Refrigeration cartridge range PG100HC-2 JH2301 1-1 fridge Integral PG250HC-2 JH2302 1-1 fridge Integral PG400HC-2 JH2303 Integral 1-1 fridge PG550HC-2 JH2304 1-1 fridge...
  • Page 6: Installation

    Adequate allowance should be made for door opening. Always ensure that the top of the cabinet is shielded from impact and moisture, with either a SKOPE-provided bench top, or with a custom or existing bench top. Installation User Manual...
  • Page 7: Ventilation

    SKOPE Pegasus Horizontal Series Prep and Pizza fridges have pan openings with lids on the top of the cabinet. Maximum air movement around the opening area of the cabinet must not exceed 0.3 m/s. Excessive air movement will cause failure of the air curtain above the pans and excessive temperature rise.
  • Page 8: Bms Connectivity

    BMS Connectivity Cabinets with the Dixell XR75CX electronic controller have RS485 ModBUS-RTU connectivity for connecting to an appropriate building management system (BMS). SKOPE recommends that you use either an optical isolator in the connection, or an RS485 to Wi-Fi converter to provide wireless connection.
  • Page 9: Legs And Castors

    SKOPE Pegasus Horizontal Series Legs and 1-1 cabinets and 2-1 leg/castor mount cabinets are packed with a set of adjustable height legs and a set of adjustable height castors. Either of these sets can be fitted to the cabinet Castors depending on specific height and manoeuvrability requirements.
  • Page 10: Shelving

    SKOPE Pegasus Horizontal Series Shelving Fitting the The cabinet is supplied with two sets of shelves and shelf support brackets per door. The shelves can be positioned at different heights to suit various products. Shelves Procedure 4: To fit the shelves 1.
  • Page 11: Pans And Lids

    SKOPE Pegasus Horizontal Series Pans and Lids Prep and Pizza cabinets are supplied with food preparation pans and sliding lids which fit into openings on top of the cabinet. For correct operation of the cabinet, the sliding lids must stay closed on the cabinet and should cover the food preparation pans when not in use.
  • Page 12: Remote Cabinets

    SKOPE Pegasus Horizontal Series Procedure 5: To fit sliding lids 1. Lift the rails from the well, leaving the ends resting on one side of the cabinet top. 2. Configure the lids as required with the notched ends meeting on the inside, and slide the lower lids into the rails.
  • Page 13: Drain

    SKOPE Pegasus Horizontal Series Table 7: Pegasus horizontal 2-1 Max. Mean Evaporating Refrigeration Condensing Liquid Operation Model ambient product temperature duty temperature temperature basis temperature temperature (SST) PG200HCr 447 watts 43°C 3.5°C 45°C 40°C -10°C 18 / 24 hours PG500HCr 534 watts 43°C...
  • Page 14: Installation Diagrams

    SKOPE Pegasus Horizontal Series Installation Refer to the diagrams for component locations and cartridge access points. Diagrams Pegasus Horizontal 1-1 installation diagram Refrig. pipes Service ports (back of cabinet) Side view Front view 19mm Mains drain tube isolation box Service ports (bottom...
  • Page 15: Operation

    Electronic Depending on the date of manufacture, the cabinet will be fitted with a Dixell XR75CX controller, a CAREL ir33 controller, or a SKOPE customised CAREL S4 EVO controller. Check Controller the label on top of the controller to verify the controller type.
  • Page 16: Pans And Lids

    (see page 5). The electronic controller also signals temperature alarms. For general operation, the electronic controller requires no initial setup or additional programming, and SKOPE does not recommend that settings be changed unless it is absolutely necessary. Open the refrigeration cartridge door to access to electronic controller for programming.
  • Page 17: Faceplate

    3.5°C for other specialist applications if required. Setpoint SKOPE does not recommend changing the setpoint unless it is absolutely necessary, and then only by small increments at a time. Procedure 6: To view and adjust the temperature setpoint for the CAREL S4 EVO 1.
  • Page 18: Messages And Alarms

    SKOPE Pegasus Horizontal Series Procedure 6: To view and adjust the temperature setpoint for the CAREL S4 EVO 4. Press the up or down button to increase or decease the setpoint value to the required temperature. 5. Press the set button to temporarily save the setpoint value.
  • Page 19: Skope Carel Ir33

    SKOPE Pegasus Horizontal Series SKOPE CAREL ir33 Faceplate Table 11: CAREL ir33 faceplate Item Icon Function Mute / program: Mutes the audible alarm (buzzer) and deactivates the alarm relay. To initiate program sets, press for 5 seconds. Up: To scroll settings up (in program mode).
  • Page 20: Temperature Setpoint

    The cabinet temperature setpoint is set at the factory, and can be adjusted if necessary. Setpoint SKOPE does not recommend changing the setpoint unless it is absolutely necessary, and then only by small increments at a time. Procedure 7: To view and adjust the temperature setpoint for the CAREL ir33 1.
  • Page 21 1. To reset the alarm, unplug the cabinet from the power supply for None Defrost over-time 1 minute, then reconnect to the power supply. limit 2. If the alarm persists, contact SKOPE. Real-time clock fault Flashing Controller E prom error...
  • Page 22: Dixell Xr75Cx

    The electronic controller can be programmed to run in energy-saving mode at specified times. When in energy saving mode the cabinet interior temperature is elevated, which may not be Mode suitable for all applications. Contact a SKOPE service agent to set this up. Faceplate 8 9 10...
  • Page 23: On/Off Function

    When the on/off function is enabled, the cabinet can be switched off and on by pressing Function button on the controller faceplate. Contact a SKOPE service agent if this function is required. When switched off, the electronic controller enters standby mode and turns off the refrigeration system, and OFF is displayed on the electronic controller faceplate.
  • Page 24: Temperature Setpoint

    The cabinet’s temperature setpoint is set at the factory, and can be adjusted if necessary. Setpoint SKOPE does not recommend changing the setpoint unless it is absolutely necessary, and then only by small increments at a time. Procedure 12: To view the temperature setpoint for the Dixell controller 1.
  • Page 25 SKOPE Pegasus Horizontal Series Table 14: Dixell controller alarms (continued) Press any button on the controller to reset the alarm. Maximum The alarm will stop once the temperature has reached an acceptable temperature alarm level. Check that the installation meets specification. Ensure there are no...
  • Page 26: Servicing

    SKOPE Pegasus Horizontal Series 4 Servicing Mains Isolation The cabinet can be isolated from the mains power supply by turning off the cabinet isolating switch and unplugging the unit supply plug, located inside the refrigeration cartridge compartment. Procedure 16: To isolate the cabinet from the power supply 1.
  • Page 27: Cleaning

    Over time, dust may accumulate within the condenser that cannot be removed with a brush. If this occurs, contact SKOPE to arrange for a SKOPE-authorised service agent to clean the condenser with compressed air. The condenser coil is located inside the refrigeration cartridge compartment and is accessed by opening the unit front cover.
  • Page 28: Lighting

    SKOPE Pegasus Horizontal Series Lighting Cabinet Pegasus 1-1 cabinets are fitted with door-activated cabinet interior lights. Depending on the cabinet size, the interior is lit by one or two 5 watt T8 LED tubes (Ø26 × 360 mm), fitted behind Interior Lights the centre pillars.
  • Page 29: Advanced Servicing

    Advanced servicing should be carried out by an authorised service agent. Detailed service and spares information is available in the SKOPE Pegasus Service Manual (MAN10711) and detailed technical information on the CAREL ir33 electronic controller can be found in the SKOPE Pegasus Technicians’...
  • Page 30 SKOPE Pegasus Horizontal Series Procedure 18: To remove the refrigeration cartridge (continued) Top clamp mechanism 6. Pull the top clamp mechanism fully forward and to the left, so that it sits on the notch on the left hand side of the refrigeration cartridge...
  • Page 31: Troubleshooting

    SKOPE Pegasus Horizontal Series Troubleshooting Table 15: Troubleshooting Problem Possible Cause Repair Cabinet not operating and no • Loss of power supply. • Check that the cabinet isolating switch is controller display turned on (see page 26). • Check the mains power supply.
  • Page 32 Trademark Infringement The SKOPE trademark on this product is infringed if the owner, for the time being, does any of the following: • Applies the trade mark to the product after its state, condition, get-up or packaging has been altered in any manner •...

This manual is also suitable for:

Pg200hcPg500prepPg800pizza