schmersal SLC 220 Operating Instructions Manual
schmersal SLC 220 Operating Instructions Manual

schmersal SLC 220 Operating Instructions Manual

Safety light curtain / safety light grid

Advertisement

Quick Links

Operating instructions
Safety light curtain / safety light grid
Operating instructions. . . . . . . . . . . .pages 1 to 14
Translation of the original operating instructions
Vous trouverez la version
FR
actuelle du mode d'emploi dans
votre langue nationale officielle
sur l'Internet,
www.schmersal.net.
U vindt de huidige versie van de
NL
gebruikshandleiding in uw
officiële landstaal op het Inter-
net, www.schmersal.net.
EU公用語で書かれた最新の取扱
JP
説明書は,インターネッ
(www.schmersal.net) からダウ
ンロードできます。
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Scope of delivery and accessories . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.6 Response time (reaction time) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.7 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.8 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.9 Cascading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3
3.1 General conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.2 Protection ield and approach . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.3 Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.4 Safety distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4
4.1 Wiring example default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5
5.1 Check before start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.3 Regular check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.4 Half-yearly inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.5 Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6
6.1 LED status information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6.2 Fault diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6.3 Extended diagnostic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Encontrará el manual de
ES
instrucciones actual en su
idioma oficial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
ufficiale UE) è scaricabile in
Internet all'indirizzo
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
8
8.1 Contact. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
9
9.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete ver-
sion in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operat-
ing instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional informa-
tion.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be
found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet: www.
schmersal.net.
EN
SLC 220
SLG 220
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLC 220 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SLC 220

  • Page 1: Table Of Contents

    5.5 Cleaning..........11 Further technical information can be found in the Schmersal Diagnostic catalogues or in the online catalogue on the Internet: www.
  • Page 2: Www.schmersal.net

    Operating instructions SLC 220 Safety light curtain / safety light grid SLG 220 The information contained in this operating instructions manual is pro- Only if the information described in this operating instruc- vided without liability and is subject to technical modifications.
  • Page 3: Technical Data

    Material of the enclosure: Aluminium Number of beams: SLC 220: 6 - 66 (default) – max. 96 (cascaded) Resolution 30 mm SLG 220: 2, 3, 4 beams Protection field heights: SLC 220: 175 mm -1675 mm default...
  • Page 4: Functions

    2.8.3 Fixed blanking The system consists of a receiver and a transmitter. For the described The SLC 220 can blank stationary parts in the protection field. functions, no further switching elements are required. For the diagnos- Multiple protection field areas can be blanked.
  • Page 5: Cascading

    2.9 Cascading The protection field of the SLC/SLG consists of the entire range located The SLC 220 (master version) can be extended with an additional light between the protection field markings of transmitter and receiver. Ad- curtain (slave) for applications with protection against stepping behind ditional protective devices must ensure that the operator has to pass by or for different monitoring ranges.
  • Page 6: Alignment

    Safety light curtain / safety light grid SLG 220 Correct installation Safety light curtain SLC 220 The safety distance for resolutions 14 mm up to 40 mm is calculated by Hazardous machine parts can only be reached means of the following formula: after passing through the protection field.
  • Page 7 Operating instructions SLC 220 Safety light curtain / safety light grid SLG 220 Safety distance to the hazardous area The following mounting heights to EN 999 must be observed: Number of Mounting height above reference floor Safety distance (S) Limit of the hazardous point...
  • Page 8: Dimensions

    4.0 to 14.0 m and cascaded systems have identical dimensions with the same protection field height. 1) For the SLC 220-E/R0175-30-RFB type, the dimension changes from 19.5 mm to 32 mm due to the extended profile length. The protection...
  • Page 9 Operating instructions SLC 220 Safety light curtain / safety light grid SLG 220 Accessories Centre fixing MS-1050 Mounting kit MS-1000 49.2 Centre support MS-1010 3. 8 38. 1...
  • Page 10: Electrical Connection

    Operating instructions SLC 220 Safety light curtain / safety light grid SLG 220 4. Electrical connection 4.1 Wiring example default Extension by master and slave Special cable for cascading Basic system: Default Optional function: Use input only for contactor control - activation through...
  • Page 11: Set-Up And Maintenance

    Operating instructions SLC 220 Safety light curtain / safety light grid SLG 220 Connector configuration Receiver, Transmitter & Cable 5.2 Maintenance SLC: Connector male Signal M12 / 8 pol. Do not use the SLC/SLG before the next inspection is termi-...
  • Page 12: Diagnostic

    Operating instructions SLC 220 Safety light curtain / safety light grid SLG 220 6. Diagnostic 6.1 LED status information Transmitter Receiver IR power Restart interlock (manual reset) External test / blanking Signal quality Function LED colour Description Function LED colour Description...
  • Page 13: Disassembly And Disposal

    Tel:+49 (0) 202 64 74 -0 Fax:+49 (0) 202 64 74- 100 You will also find detailed information regarding our product variety on our website: www. schmersal.com Repair handling / shipping: Safety Control GmbH Am Industriepark 11 D-84453 Mühldorf / Inn...
  • Page 14: Operating Instructions

    Christian Spranger Klaus Schuster Managing Director Managing Director The currently valid declaration of conformity can be down- loaded from the internet at www.schmersal.net. Safety Control GmbH Am Industriepark 33 D-84453 Mühldorf / Inn Telefon +49 - (0)86 31 - 187 - 9 60...

This manual is also suitable for:

Slg 220

Table of Contents