Growatt SPA TL3 BH-UP Series Installation & Operation Manual

Growatt SPA TL3 BH-UP Series Installation & Operation Manual

Advertisement

Growatt New Energy
Download
Manual
Shenzhen Growatt New Energy Co., Ltd
4-13/F,Building A,Sino-German(Europe) Industrial Park,
Hangcheng Ave, Bao'an District, Shenzhen, China
T
+86 0755 2747 1942
E
service@ginverter.com
www.ginverter.com
W
GR-UM-245-A-01
Installation
&
Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPA TL3 BH-UP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Growatt SPA TL3 BH-UP Series

  • Page 1 Installation & Operation Manual Growatt New Energy Download Manual Shenzhen Growatt New Energy Co., Ltd 4-13/F,Building A,Sino-German(Europe) Industrial Park, Hangcheng Ave, Bao'an District, Shenzhen, China +86 0755 2747 1942 service@ginverter.com www.ginverter.com GR-UM-245-A-01...
  • Page 2: Table Of Contents

    2 Safety 2.1 Purpose Use 2.2 Safety Measure 2.3 Symbols introduction on the SPA inverter 3 Product Description 3.1 Growatt SPA series inverter 3.2 Label Explanation 3.3 Size and weight 3.4 The advantage of the unit of Growatt SPA Unpacking 5 Installation 5.1 Basic installation requirements...
  • Page 3 11.4 Disposing of theSPA inverter 6.4 Display and button 6.5 Communication 12 Product specification Start-up and shut down 12.1 Growatt SPA series energy 7.1 Start-up the SPA system SPA system storage machine product specification 7.2 Disconnect the SPA system 12.2 DC input terminal parameter 12.3 Torque...
  • Page 4: Brief Introduction

    1.3 Product Description Rj45 interface of DRMs(used only in Australia) Growatt SPA TL3 BH-UP Series is used to store energy generated from grid if it is allowed Rs485 communication interface of meter1 in the battery, also energy can be sent to power grid through SPA TL3 BH-UP for self CAN communication interface of Lithium battery consumption or when Grid power is lost, SPA TL3 BH-UP can be used as backup power.
  • Page 5: Safety Measure

    1.4 Safety Instructions 1.Please be clear which kind of battery system you want, lithium battery system or lead- As shown above, a complete grid-connected system of SPA consists of SPA inverter, acid battery system, if you choose the wrong system, SPA can't work normally. battery, utility grid and other components.
  • Page 6: Growatt Spa Series Inverter

    Nominal AC output 50/60 Hz 3 Product Description frequency Battery data Battery voltage range 100-550 d.c.V 3.1 Growatt SPA series inverter Max. charging and 25 d.c.A discharging current Marks of SPA Type of battery Lithium / Lead-acid Mark Description...
  • Page 7: Size And Weight

    Lithium / Lead-acid Growatt SPA TL3 BH-UP 198.5 453.5 Others Safety level ClassⅠ 3.4 The advantage of the unit of Growatt SPA Ingress Protection IP65 Features below: Operation Ambient Temperature -25℃~+60℃ Ø All in one design. Can improve self consumption, back up and also pinch the valley.
  • Page 8: Basic Installation Requirements

    A. The installation location must be suitable for SPA's weight for a long period time. please contact with supplier. B. The installation location must conforms with dimension of SPA. Growatt SPA series and accessories shows as follows: C. Do not install the unit on structures constructed of flammable or thermo labile materials.
  • Page 9: Installation Requires Tools And Rj 45 Terminal Sequence Of The Lan Line

    H. Installation position shall not prevent access to the disconnection means. I. In order to ensure machine can run normally and easy to operate, please pay attention Description to provide adequate space for SPA, Please refer to below: Press the RJ45 terminal Press battery terminal connector Disconnect battery terminal Unscrew nut...
  • Page 10: Installation Instructions

    4.Drill four Ф8 holes at the mark point, the depth is not less than 55mm. 5.Knock four explosion bolt into Ф8 holes (As the chart 5.8b below). Growatt SPA4000-10000TL3 BH-UP only use meter as its sensor, before installing your 6.Hang the energy storage machine on the four setscrews (As the chart 5.8c below).
  • Page 11 Wire suggest length: Step 3: Push threaded sleeve on to connection terminal until both are locked tightly. max cable length conductor cross section Growatt Growatt Growatt Growatt Growatt Growatt SPA 4000 SPA 5000 SPA 6000 SPA 7000 SPA 8000 SPA 10000...
  • Page 12 The recommended wiring diagram is as follows: Chart 5.15 Step 3: Push threaded sleeve on to connection terminal until both are locked tightly. Chart 5.19 Note: Chart 5.16 This diagram is an example for gird system without special requirement on electrical wiring connection.The neutral line is necessary.
  • Page 13 5.4.3 Connection of battery terminal Similar to the traditional inverter connecting, the input of battery can be realized by using MC4 terminal, the detail steps are as follows: Step 1: Turn off battery switch. SPA Inverter Step 2: Insert battery panel positive and negative cables into MC4 terminal,then Battery connect positive pole(+) of connection cable to positive pole(+) of battery input ACGRID...
  • Page 14 Step9: Screw the swivel nut onto the waterproof cover. Note: Chart 5.25 1. Meter must be provided by Growatt. If not, maybe meter can't communicate with SPA inverter. Remark: 2. The more detail describe of meter installation, please turn to meter user manual.
  • Page 15 5.4.6 Connection of RS 485 terminal RS 485 reserved communication interface, can be used for meter communication, please connect the terminal (RJ45) as follows: Step1: Unscrew the swivel nut from the cable gland. Step2: Thread the swivel nut over the “RS485” cable. Step3: Press the cable support sleeve out of the cable gland.
  • Page 16 RJ45 terminal pin assignment 5.4.7 Connection of DRMS terminal(Australia only) assignment for inverter scapable of both charging and discharging When SPA is applied to Australia, the DRMS terminals need to be connected, the connection way appears as follows: DRM5 Step1: Unscrew the swivel nut from the cable gland. DRM6 Step2: Thread the swivel nut over the “DRMS”...
  • Page 17 5.4.9 Connection of Dry contact The dry contact is used to communicate with external devices (such as remote start hot water heater). The wiring steps are as follows: Step1: Unscrew the swivel nut from the cable gland. Step2: Thread the swivel nut over the cable. Step3: Press the cable support sleeve out of the cable gland.
  • Page 18: Commissioning 6

    Commissioning 6 6.1 Commissioning of SPA 5.4.10 Grounding connection Electrify SPA after all installation of Part5 be finished, here are the steps: SPA must be grounded by cable, the grounding point is showed as follow, and the minimum grounding cable wire diameter is 10.0mm . Ø...
  • Page 19 6.3 Country setting User only can set one period for battery first and Grid first on the LCD, if user need set Growatt can provide various regulations of the machine, after customers receive the more pleases login shineserver. machine, according to their country/region, by LCD to set the corresponding regulations.
  • Page 20 6.4 Display and button VDE0126 GT0XXXXXX1 TUNISIA (NULL) 6.4.1 LCD display area Ukraine (NULL) VDE-AR-N4105 GT0XXXXXX7 IEC62116&61727 GT0XXXXXXC General model South Africa GT1XXXXXXC(NULL) Dubai (NULL) Chile (NULL) Normal Vb / Cb: 488.0 V 88% Argentina (NULL) Uruguay (NULL) Others (NULL) CEI 0-21 GT0XXXXXX4 Italy...
  • Page 21 6.4.2 LED and button instruction The A line's concluding information as follow: Ø Standby state: SPA is in standby state. No error in this state, but for other reasons, make it in a wait state. Ø Normal state: SPA is normal working state. Ø...
  • Page 22 6.4.4 work mode set up 1.Under the Basic Para, you can see the setup options below after pressing Enter for 1S: Press “Enter ” key Press “Enter” key You can enter set up page by long press “enter” for 3S, in this page, you can press more than 1 seconds more than 1 seconds “enter”...
  • Page 23 Note: 4.Under the Mode Change, you can see the setup options below after pressing Enter: 1.When EPS Disable & Bypass: OFF, there is no output at the EPS port under any circumstances; Press “enter ” key to Press “enter ” key to 2.When EPS Enable &...
  • Page 24 Note: Note: 1.When the ExportLimit is set to ON and the SingleLimit is OFF, the total Export Limit 1.After each step of the test is OK, the LCD displays PASS, wait for 10s and then proceed function takes effect. to the next test. 2.When the ExportLimit is set to ON and the SingleLimit is ON, the phase-level export 2.After detecting Fail, you need to press OK to exit.
  • Page 25 8. Under the Country/Area setting, you can change the safety options of SPA after 10.Under the default set, you can see the setup options below after pressing Enter: pressing Enter: Press “enter” key to Press “enter” key more make sure than 3 seconds to make sure WorkMode Europe Area...
  • Page 26 6.5.2 Use of 485-1/485-2 port When set to Meter2 mode, the wiring diagram is as follows: 485-1/485-2 port is the extended 485 interface on SPA, which needs to be used in conjunction with the RS485 Setting in the LCD menu to communicate with external devices.
  • Page 27 SPA. Note: This monitoring devices can only be used with Growatt's Shineserver / shinephone monitor platform. Wi-Fi-X / Shinelink are connect with inverter via USB interface and use computer terminal / or mobile phone for data monitoring.
  • Page 28: Start-Up The Spa System

    1.Connect to Grid. SPA inverter stops working. Growatt SPA series inverter without fan so belongs to 2.Connect to Battery. natural cooling, hot air from the top of the radiator, tie-in battery, use environment for 3.Turn the switch on in turn of Grid, battery.
  • Page 29 Output DC current too high. 1.Restart inverter. Please refer to the local grid 2.Please contact Growatt service 9.1 System fault information list and troubleshooting Output High DCI standard for disconnection center if restart can't solve the...
  • Page 30: Decommissioning 11

    2.Restart inverter again. •2014/30/EU Electromagnetic Compatibility Directive (EMC) •2011/65/EU RoHS Directive and its amendment (EU)2015/863 Shenzhen Growatt New Energy Technology Co. Ltd confirms that the Growatt inverters and accessories described in this document are in compliance with the above mentioned Error message EU directives.
  • Page 31: Growatt Spa Series Energy Storage Machine Product Specification

    12 Product specification 12.1 Growatt SPH series energy storage machine product Capacity of battery 7.68~76.8kWh specification Efficiency Max. efficiency 97.6% 97.8% 98.0% 98.2% 98.2% 98.2% Model SPA 4000 SPA 5000 SPA 6000 SPA 7000 SPA 8000 SPA 10K Euro-eta 97.0% 97.2%...
  • Page 32: Dc Input Terminal Parameter

    The following chart is the energy storage machine optional appendix list, if there is a RF/WIFI/GPRS/4G optional need please contact the Growatt New Energy Technology Co., Ltd or dealer orders.(P/N is Warranty: 5 / 10 years yes / optional only for reference,and it may be changed)
  • Page 33 13 Certificate Annex: Growatt SPA series inverter apply within the scope of the world, So the inverter have to AutoTest (only for Italy) satisfy different countries and regions of different safety standards. Follow is the chart of Auto Test, refer to 6.4.4. in the set up surface of “Auto Test”. Press the “enter”...