Pip Control Circuits - Sanyo AVM-2550S Training Manual

Hide thumbs Also See for AVM-2550S:
Table of Contents

Advertisement

The AVM-2780G provides for Picture In Picture (PIP) function through
IC8001, the PIP Signal Processor IC.
The PIP circuits perform PIP On/Off, PIP Swap, PIP Location, PIP Freeze and
PIP Select functions.
The PIP functions are operated using the remote control transmitter.
The PIP circuits are controlled by the PIP Signal Processor IC8001 through
the CPU IC801. The PIP Signal Processor IC8001 requires 6 inputs: the
CPU
(POWER:OFF ON)
IC8001
(POWER ON RESET)
CPU
(BUS SDA)
CPU
(BUS SCL)
IC8001
(ACK)
Condition
PIP CONTROL CIRCUIT
POWER ON
160ms
5V
0V
H
L
MSB
1
2
7
Start
S IC Address
S = Start bit
A = Acknowledge bit
P = Stop bit
PIP Control Data Signals (BUS Data Transfer)
CPU, the horizontal and vertical sync circuits, the PIP sync separation circuit
and the PIP 3.3 VDC supply circuit. There are two inputs from CPU; the SDA
(Serial Data) input/output from pin 32, and the SCL (Serial Clock) input from
pin 34. The Data signals control the PIP On/Off, the PIP Swap, PIP Location,
PIP Freeze and PIP Select functions. When the power is switched On, the 12
VDC and PIP 3.3 VDC supply lines will gradually rise. At 60ms after pin 27 of
the CPU goes High, IC8001 will execute a Power On Reset, initializing all
internal registers to 0 (zero) and resetting the BUS interface.
60ms
PIP Power On Reset
MSB
8
9
1
2
ACK
0
A
Sub Address
A
Data Byte
n Bytes
IC Address = 24 hex (00100100)
Sub Address = auto-increments
– 56 –
7
8
9
ACK
Stop
Condition
A P