Table of Contents

Advertisement

en Troubleshooting
Fault
Appliance door cannot be
closed.
Lid on the detergent dis-
penser cannot be closed.

Noise

Fault
Filling valves making knock-
ing noises.
Knocking or rattling noise.
54
Cause
Door cannot be closed due
to installation method.
Detergent dispenser or lid
are blocked by sticky deter-
gent residue.
Cause
Caused by the domestic in-
stallation. No appliance fault
present. Does not affect
functioning of the appliance.
Spray arm is striking table-
ware.
With a small load the water
jets directly strike against
the tub.
Light items of tableware
move about during the wash
cycle.
Troubleshooting
Check whether the appliance has
been installed properly.
When closed, the appliance door,
its decor or attached parts should
not knock against adjacent cabin-
ets or the worktop.
Remove detergent residue.
Troubleshooting
Can only be remedied in the do-
mestic installation.
Arrange tableware so that the spray
arms do not strike tableware.
Distribute the tableware evenly.
Load the appliance with more table-
ware.
Position light items of tableware se-
curely.

Advertisement

Table of Contents
loading

Table of Contents