Dry And Wet Contact Digital Output (Cn24) - Asus AAEON BOXER-6403M User Manual

Hide thumbs Also See for AAEON BOXER-6403M:
Table of Contents

Advertisement

2
Digital input 2
3
Digital input 1
4
Digital input 0
5
WET contact POWER

2.3.8 Dry and Wet Contact Digital Output (CN24)

Dry Contact Wiring
Digital output voltage range
Max
30 V
Pin
Pin Name
1
GND
2
Digital output 5
3
Digital output 4
4
Digital output POWER
5
GND
Chapter 2 – Hardware Information
Input
Input
Input
PWR
Wet Contact Wiring
User I/O Level
Min
5 V
Signal Type
GND
Input
Input
Input
GND
DRY (5V) WET (3~30V)
DRY (5V) WET (3~30V)
DRY (5V) WET (3~30V)
3~30V
Signal Level
Open collector to 30 VDC
Open collector to 30 VDC
3 ~ 30 V
17