Hacousto Holland bv Industrieweg 87 2651BC Berkel & Rodenrijs Author: 4E-IMPACT reference manual SUMMARY This document describes specifications, functions, configuration settings and interfaces of the 4EVAC IMPACT Voice Evacuation System. Rev. Date Nature of Changes Approved By REVISION AND APPROVAL...
Page 2
Hacousto Holland bv Industrieweg 87 2651BC Berkel & Rodenrijs Author: 4E-IMPACT reference manual Table of Contents 1. What is the 4E-FSC? ................................3 2. Installation ......................... Fout! Bladwijzer niet gedefinieerd. 3. Connection diagram ................................4 4. Network cabling ..................................4 5.
Page 3
2.1.3. 4E-SW6 zone switching module Peripherals IMPACT is fully compatible with all L-Net devices as well as the Compact 500 system. Impact and Compact systems both can work in one network, sharing the same configuration data. Page 3 of 8...
Page 4
3. Connection diagram 4. Network cabling The 4EVAC network features a full duplex RS-422 data link and 24V DC power to remote devices. If you’re building a distributed system using the 4EVAC network, you should make physical links between devices using the right cables. The cabling should meet the following requirements:...
Page 5
Industrieweg 87 2651BC Berkel & Rodenrijs Author: 4E-IMPACT reference manual 4. Shield required (at least FTP) NOTE: If you use a straight cable, the device will power up but the Tx/Rx data terminals will not be properly connected. This will result in a communication fault.
Page 6
Hacousto Holland bv Industrieweg 87 2651BC Berkel & Rodenrijs Author: 4E-IMPACT reference manual 5. Technical specifications CONTROLLER Maximum number of zones Standalone 96 (16 x 4E-SW6) Network 255 (max. system capacity) Inputs Outputs Network interface Maximum range (optical) 2000 m...
Page 7
Hacousto Holland bv Industrieweg 87 2651BC Berkel & Rodenrijs Author: 4E-IMPACT reference manual Inputs Outputs Charger Type Autonomous EN54-4 compliant charger with thermal correction Parallel operation Max. 3 x DCA2.500 (1 x master + 2 x slave) Max. charging current Battery type 24V (2x12V) maintenance-free, lead-acid, sealed, for stationary buffer operation.
Page 8
Author: 4E-IMPACT reference manual M A D E T H E N E T H E R L A N D S 4EVAC is a trade name of: Hacousto Holland bv Industrieweg 87 2651BC Berkel & Rodenrijs The Netherlands www.4EVAC.com...