Maintenance - Makita GA031G Instruction Manual

Cordless angle grinder
Hide thumbs Also See for GA031G:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
State of abnormality
The vacuum cleaner does not run
along with the switch operation of
the tool.
The vacuum cleaner runs while the
tool's switch trigger is not pulled.

MAINTENANCE

CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before attempting to perform inspection or
maintenance.
NOTICE:
Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
To maintain product SAFETY and RELIABILITY, repairs,
any other maintenance or adjustment should be per-
formed by Makita Authorized Service Centers, always
using Makita replacement parts.
Probable cause (malfunction)
The wireless unit is not installed into
the tool.
The wireless unit is improperly installed
into the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The wireless activation button on the
tool has not been pushed.
The stand-by switch on the vacuum
cleaner is not set to "AUTO".
More than 10 tools are registered to the
vacuum cleaner.
The vacuum cleaner erased all tool
registrations.
No power supply
The tool and vacuum cleaner are away
from each other (out of the transmission
range).
Radio disturbance by other appliances
which generate high-intensity radio
waves.
Other users are using the wireless
activation of the vacuum cleaner with
their tools.
23 ENGLISH
Remedy
Install the wireless unit correctly.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot.
Push the wireless activation button briefly and make
sure that the wireless activation lamp is blinking
in blue.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
Perform the tool registration again.
If more than 10 tools are registered to the vacuum
cleaner, the tool registered earliest will be cancelled
automatically.
Perform the tool registration again.
Supply the power to the tool and the vacuum
cleaner.
Get the tool and vacuum cleaner closer each other.
The maximum transmission distance is approxi-
mately 10 m however it may vary according to the
circumstances.
Keep the tool and vacuum cleaner away from the
appliances such as Wi-Fi devices and microwave
ovens.
Turn off the wireless activation button of the other
tools or cancel the tool registration of the other
tools.
Air vent cleaning
The tool and its air vents have to be kept clean.
Regularly clean the tool's air vents or whenever the
vents start to become obstructed.
► Fig.44: 1. Exhaust vent 2. Inhalation vent
Remove the dust cover from inhalation vent and clean it
for smooth air circulation.
► Fig.45: 1. Dust cover
NOTICE:
Clean out the dust cover when it is
clogged with dust or foreign matters. Continuing
operation with a clogged dust cover may damage the
tool.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga028gGa029gGa030gGa027gGa032gGa028gz

Table of Contents