Page 58
12 V DC Output Ports Power Supply: 12 V DC, 1 A / 2 A Max Connects to Provides 12 V DC power to independent hardware devices.
Page 59
12 V DC Output Ports Power Supply: 12 V DC, 1 A / 2 A Max Connects to Switch, Screen, Projector Lift, Lighting, Motorized Equipment, Motion Device, etc. Provides 12 V DC power for the relay loop.
Page 60
12 V DC Output Ports Power Supply: 12 V DC, 1 A / 2 A Max Provides 12 V DC power for the digital output loop. Connects to Switch, Screen, Projector Lift, Lighting and Equipment Control.
Page 61
12 V DC Output Ports Power Supply: 12 V DC, 1 A / 2 A Max Provides 12 V DC power for the digital output loop. Provides connection to digital output #2. Provides connection to digital output #1.
Relay Channels NO, Isolated Relays: 24 V DC 2 A Max Normally Closed Open Connects to Switch, Screen, Projector Lift, Lighting, Motorized Equipment, Motion Device, etc.
Page 63
TTL Level (0 ~ 5 V) Carrier Frequency: 10 ~ 455 kHz RS-232 Ports Unidirectional (0 ~ 5 V or +/-5 V) Baud Rate: 300 to 115200 (default: 9600) Data Bit: 8 (default) or 7 Stop Bit: 1 (default) or 2 Parity: None (default), Even or Connects to IR: Blu-ray / DVD Player, TV,...
Page 64
IR Receiver IR Receiver Unidirectional IR 2 x IR Transmitters...
Page 65
Programmable Digital Input Channels Digital Input VDC Mode: -Input Voltage Range: 0 ~ 24 V DC -Programmable Range: 1 ~ 24 VDC Dry Contact Mode: -Pull-up 2 k to + 12 V DC Connects to Digital Input: Switches, Sensors Monitors and Button Triggers.
Page 66
Programmable Digital Output Channels Digital Output: 300 mA sink from 24 V DC Connects to Digital Output: Switch, Screen, Projector Lift, Lighting and Equipment Control. Relay Module...
Page 67
Bidirectional RS-232 Ports Baud Rate: 300 to 115200 (default: 9600) Data Bit: 8 (default) or 7 Stop Bit: 1 (default) or 2 Parity: None (default), even or Connects to Projector, Matrix Switch, Camera, etc.
Page 68
Programmable Bidirectional RS-232/422/485 Ports Configurable by pin assignment Baud Rate: 300 to 115200 (default: 9600) Data Bit: 8 (default) or 7 Stop Bit: 1 (default) or 2 Parity: None (default), Even or Flow Control: None (default) or RTS/CTS Connects to Projector, Matrix Switch, Camera, etc.
Page 69
Bidirectional RS-232 / 422 / 485 Ports Configurable by pin assignment Connects to Projector, Matrix Switch, Camera, etc.
Page 70
The RJ-45 port is used to connect and access TCP, UDP, PJLink, ONVIF, HTTP, HTTPS, and Telnet devices. Ethernet / VK1200 / 2200 can operate as a Control LAN DHCP server for assigning IP addresses to the devices ONVIF PJLink Ethernet Switch Telnet Modular Matrix Switch...
Page 71
Front View Rear View Side View Front View Side View Rear View...
Page 75
RS-232 Projector Video Switch Relay Dry Contact Device Lighting Control Door Sensor Screen PoE Switch Projector Projector Lift Conference Network System Ethernet Cable Camera Dry Contact Door Device Sensor RS-232 Projector Video Switch Relay Lighting Control PoE Switch Projector Screen Conference Network System...
Page 79
Bidirectional RS-232 Ports Baud Rate: 300 to 115200 (default: 9600) Data Bit: 8 (default) or 7 Stop Bit: 1 (default) or 2 Parity: None (default), even or Connects to Projector, Matrix Switch, Camera, etc.
Page 80
2 x Relay Channels Normally Open, Isolated Relays Contact Rating: 24VDC 1A Max Normally Closed Open Connects to Switch, Screen, Projector Lift, Lighting, Motorized Equipment, Motion Device, etc.
Page 81
1 x Programmable Digital Input Channel Digital Input VDC Mode: -Input Voltage Range: 0 to 5 VDC -Programmable Range: 1 to 5 VDC Dry Contact Mode: -Pull-up 2k ohms to + 5 VDC Connects to Digital Input: Switches, Sensors, Monitors, or Button...
Page 82
The RJ-45 port is used to connect and access TCP, UDP, PJLink, ONVIF, HTTP, HTTPS, and Telnet Ethernet devices. ONVIF PJLink Ethernet Switch Telnet Modular Matrix Switch Telnet VK224 KNX IP Interface VK236 OUTLET STATUS SE LEC T OUTLET SENSOR SENSOR CURRENT CURRENT...
Page 83
VK224 (Rear) Network OUTLET STATUS S E LE CT OUTLET SENSOR SENSOR CURRENT CURRENT ADDRESS Control Box Power Distribution Video Matrix Projector Camera Unit Serial Devices Ethernet Serial The available Expansion Box models include:...
Page 84
ATEN Keypad Screen BD-Player Powered by PoE or DC 5V Ethernet Switch VK1100 (Rear) Light Projector Video Switch ...
Page 85
Rear View Front View Side View Side View...
Page 86
Front View Rear View Side View Side View ...
Page 190
The Button/Slider Bar Actions panel consists of the following elements:...
Page 191
You can configure a button with Device commands (On, Off, Stop, Play, etc.); as a Macro to send multiple commands to one or more devices; or as a Link to other Viewer pages. Advanced Options allow you to add conditions to the commands, as described on the next page.
Page 251
ATEN and third-party devices. One ATEN control system allows management from up to two Unizon™ servers. Note that a license is required for using Unizon™. For more information, see ATEN Unizon™ User Manual. When an ATEN-controller-managed AV device is added to Unizon™, the following information is available in the Unizon™...
Page 282
Type the part of the WebSocket URI that follows its communication port. For example, if the URI is Type the subprotocol for the Ethernet device. This Type the required data for the Sec-WebSocket-...