Sensica SensiLight Mini User Manual
Hide thumbs Also See for SensiLight Mini:

Advertisement

Mini
my permanent hair reduction
User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SensiLight Mini and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sensica SensiLight Mini

  • Page 1 Mini my permanent hair reduction User Guide...
  • Page 3: Table Of Contents

    Table of contents What is sensiLight™ Mini RPL (Reactive Pulsed Light)™ technology - How does it work Long-term hair reduction – Hair growth cycle sensiLight™ Mini device description Handheld description User interface description Who should use and how to decide to use sensiLight™ Mini When shouldn’t sensiLight™...
  • Page 4: What Is Sensilight™ Mini

    START TREATING WITH SENSILIGHT™ MINI. THE USER GUIDE AS WELL AS AN dissipates into the follicle and generates INSTRUCTIONAL VIDEO CAN ALSO BE local thermal damage, causing a reduction FOUND AT WWW.SENSICA.COM in hair growth.
  • Page 5: Sensilight™ Mini Device Description

    sensiLight™ Mini device description The sensiLight™ Mini package consists of the following main components: • sensiLight™ Mini handheld device • External power supply Handheld description 1-3 energy level lights Skin tone and ON/OFF button contact sensor and energy level (Fitzpatrick sensor) button Power supply socket...
  • Page 6: User Interface Description

    User interface description The user interface and control capabilities include the following features: 1. ON/OFF and energy selection button • Single button used for the device activation, deactivation, and energy selection. • Pressing the button (after the device is connected to the power supply) will turn the device on at energy level 1.
  • Page 7 Indicator Mode No light Device not working (not connected to the power supply). “Blinking” Device is in standby mode (before powering on or when Standby green light left unattended for 3 minutes). 1-3 energy level Energy The three energy levels are indicated by three green lights level 1-3 LED lights.
  • Page 8: Who Should Use And How To Decide To Use Sensilight™ Mini

    Who should use and how to NEVER USE SENSILIGHT™ MINI decide to use sensiLight™ Mini AROUND OR NEAR YOUR EYES. • sensiLight™ Mini is intended for women When shouldn’t sensiLight™ and men who desire to remove unwanted Mini be used hair.
  • Page 9: What You Must Do To Avoid Serious Harm - Warnings

    suffer from epilepsy, it could trigger a greater risk of delayed healing and seizure. infection in the case of an adverse effect. • Do not use on damaged or broken skin or • Do not use if you have had a skin peel if you have a history of Herpes or Psoriasis or other skin resurfacing procedure outbreak in the treatment area since it can...
  • Page 10: What You Must Do To Avoid Other Harm - Cautions

    • Never look directly at the light coming • Do not use the sensiLight™ Mini on from the sensiLight™ Mini applicator and mucous membranes such as nostrils, lips lamp as it may cause eye injury. of the mouth, eyelids, ears, genital area and the anus as it may lead to serious •...
  • Page 11 • This appliance is not intended for use by Note: persons with reduced physical, sensory or Do not share sensiLight™ Mini at mental capabilities. any time, due to the possibility of transmitting diseases between users. • Do not use the device if: Use sensiLight™...
  • Page 12: Possible Side Effects

    Possible side effects • Skin irritation - The use of Pulsed Light Hair Removal System is generally very When using the sensiLight™ Mini well- tolerated, the majority of users do according to the instructions for use, side feel a sensation of warmth and a mild effects are rare.
  • Page 13: Benefits

    and, extremely rarely, may leave a visible decreased after 2 to 7 days and you should treat the area by applying ice. You should permanent scar. avoid exposure to sun. • Scarring - In rare cases, permanent • Infection- In rare cases, infection of the scarring may occur.
  • Page 14 As an extra precaution, sensiLight™ Mini has been designed to only emit a light pulse when it is in contact with your skin. Response to sensiLight™ Mini hair reduction differs between individuals depending on biological factors and how closely treatment instructions are followed.
  • Page 15: User Instructions

    User instructions other applications containing alcohol) or acetone to clean the skin one hour before sensiLight™ Mini is an optimal solution for using sensiLight™ Mini as it may cause all treatment areas, such as your underarms, burning of the skin. bikini line, arms, back, shoulders, chest and legs.
  • Page 16: Preliminary Test

    Preliminary test 6. Wait 48 hours and examine the tested area. The preliminary test is intended to determine your skins reaction to the If the skin in the test area seems normal (no sensiLight™ Mini treatment and help you set response or mild redness observed), you can the optimal energy level for each treatment proceed with a full treatment in the highest...
  • Page 17 until the entire treatment are has been preliminary test section). The energy level lights will light up green on the level scale covered and while constantly pressing according to the selected energy level. the trigger button by “gliding” it to the next spot to be treated.
  • Page 18: Recommended Treatment Protocol

    Recommended treatment protocol Treatment areas depending on hair color and their treatment protocol Average Fitzpatrick Treatment Treatment Hair color Energy levels number of skin level area interval treatments Legs The 1–4 Arms Light brown 1–4 inclusive 1–3 10–12 treatments to brown Underarms will be Bikini lines...
  • Page 19: What To Expect When Using The Sensilight™ Mini

    Post-treatment care • Maintenance will be needed from time to time if growth is still visible. • Apply a calming lotion such as Aloe Vera. • You may use the treatment log at the end • Avoid using peeling and bleaching creams of this manual, in order to assist you with or products for at least 24 hours as this recording your specific treatments areas,...
  • Page 20: Troubleshooting

    bathtubs, showers, basins or other vessels pulse only when the device is in full containing water as this may cause severe contact with the skin. electrocution. • Verify that the area you are trying to treat is not too small, curved or bony to treat. •...
  • Page 21: Customer Service

    • If you still have problems with your device, please contact our customer service. Customer service For more information about sensiLight™ Mini or if your sensiLight™ Mini is broken, quits working or you need more assistance, please contact us: 855-SENSICA (855-736-7422) support@sensica.com...
  • Page 22: Device Specification Parameters

    Device specification Storage instructions parameters Emitted light spectrum: Storage and transport conditions 475 [nm] to 1,200 [nm] max. -10 º C to 70 º C (14 º F to 158 º F) Temperature Emitted energy flux: 5 [J/cm²] Selectable energy levels: 3 levels 0 to 90% RH at 55 º...
  • Page 23: Electromagnetic Compatibility (Emc) And Specifications

    • The use of accessories or replacement should be observed to verify normal parts, other than those sold/specified operation in the configuration in which it by sensica International, may result will be used. EMC Information Guidance and manufacturer’s declaration – electromagnetic emissions as per IEC 60601-1-2: 2007 - Table 1 The SensiLight™Mini is intended for use in the electromagnetic environment...
  • Page 24 Guidance and manufacturer’s declaration – electromagnetic immunity as per IEC 60601-1-2: 2007 - Table 2 The SensiLight™Mini is intended for use in the electromagnetic environment specified below. The customer or the user of the SensiLight™Mini should assure that it is used in such an environment.
  • Page 25 Guidance and manufacturer’s declaration – electromagnetic immunity As per IEC 60601-1-2: 2007 - Table 4 The SensiLight™Mini is intended for use in the electromagnetic environment specified below. The customer or the user of the SensiLight™Mini should assure that it is used in such an environment. Immunity IEC 60601 Compliance...
  • Page 26 Recommended separation distances between portable and mobile RF communications equipment and the SensiLight™Mini as per IEC 60601-1-2: 2007 - Table 6 The SensiLight™Mini is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the SensiLight™Mini can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the SensiLight™Mini as recommended below, according to the maximum output power of the communications equipment.
  • Page 27: Treatment Log

    Treatment log Treatment date Treated area Comments...
  • Page 28 Treatment log Treatment date Treated area Comments...
  • Page 29 Treatment log Treatment date Treated area Comments...
  • Page 30 Treatment log Treatment date Treated area Comments MD-04104-A0...
  • Page 31: Labeling

    Labeling Model: IPL030US Power: 100 ÷ 240V x A50 ÷ 60Hz Double insulation Keep away from eyes Type BF equipment Please read all warnings and safety precautions prior to use Consult Instructions for use Do not use sensiLight™ Mini device on tanned skin or after sun exposure Do not let the device become Do not dispose...
  • Page 32 Fitzpatrick skin type scale Do not use sensiLight™ Mini on naturally dark skin types. Distributed by Sensica Inc. 392 Summit Ave. Jersey City, NJ 07306, USA 855- SENSICA (855-736-7422) support@sensica.com visit us: www.sensica.com...

Table of Contents