KitchenAid KBNU367TSS Installation Instructions And Use & Care Manual page 12

Outdoor grills freestanding and built-in
Table of Contents

Advertisement

Available languages

Available languages

6. Attach condiment shelf (on some models) to the inside of the
left cabinet door.
A. Attachment holes
B. Condiment shelf
7. Dispose of/recycle all packaging material.
Make Gas Connection
WARNING
Explosion Hazard
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
If converting to Natural gas, see conversion kit requirements in
the "Gas Supply Requirements" section. Follow instructions
included with kit.
LP Gas:
IMPORTANT: A 20 lb LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose assembly
supplied with the grill must be used. Replacement gas pressure
regulator/hose assembly specific to your model, is available from
your outdoor grill dealer.
To Install the 20 lb LP Gas Fuel Tank:
1. Open the 20 lb LP gas fuel tank drawer.
2. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
12
A
B
3. Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
A
A. Locking screw
B. Mounting hole
C. Bottom collar
4. Screw the gas pressure regulator/hose assembly to the 20 lb
LP gas fuel tank as shown.
A
A. 20 lb LP gas fuel tank
B. Gas pressure regulator/hose assembly
5. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
6. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
7. Slide tank drawer back into the cabinet.
8. Go to "Check and Adjust the Burners" section.
If Converted to Natural Gas
WARNING
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1, or CAN/CGA-
B149.1 Natural Gas and Propane installation code.
B
C
B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbnu487tssKfru368tKfru488tKbnu367tKbnu487t

Table of Contents