Click " Connect " untill the Status displays "disconnected" to "connected". It means the WS433-CL-04 is
being connected with computer;
Next, we need to import the configuration file for WS433-CL-04 by importing the csv file: Go to MENU: FILE /
Import New / => select the template file.
Step 3: Configure parameters of the sensor.
Memmap resgisters
You can download Modbus Memmap of WS433-CL with the following link:
https://filerun.daviteq.com/wl/?id=BKEaUzdArkoc0Hc7nfpRShdPVToVrqQZ
In the memmap file, refer to the Memmap of WS433-AI sheet to configure the sensor's operating parameters
accordingly.
The reference memmap addresses are based on the order of the sensors added in the Memmap file
above
Typical sensor parameters:
Function
Function
Code
Code
(Read)
(Write)
4
# of
Byte Size
Description
register
%Battery
1
2
of sensor
Node
Value
Default
Range
10,30,60,99
uint16
Format
Property
Explanation
Battery
level, only
04 levels:
10%, 30%,
60% and
Read
99% (full).
When 10%
==> Need
to replace
the battery