Falcon G1808X Installation & Servicing Instructions Manual

Falcon G1808X Installation & Servicing Instructions Manual

Advertisement

G1808X, G1838X, G1848X Fryers
INSTALLATION and
SERVICING INSTRUCTIONS
This appliance must be installed and serviced by a competent person as stipulated by the
Gas Safety (Installation & Use) Regulations.
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation. Particular attention MUST be paid to:
Gas Safety (Installation & Use) Regulations
Health and Safety at Work etc. Act
Local and National Building Regulations
Fire Precautions Act
The appliance has been CE-marked on the basis of compliance with the Gas Appliance Directive for
the Countries, Gas Types and Pressures as stated on the data plate.
WARNING
TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC,
:
MUST BE EARTHED.
On completion of the installation, these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the Appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a maintenance
contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out
adjustments and repairs. A quotation will be given upon request to the contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement
parts in a safe manner, via a licenced waste handler.
Units are designed to be dismantled easily and recycling of all
material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000
Fax: 01438 369 900
Detailed recommendations are contained in
Institute of Gas Engineers published documents:
IGE/UP1, IGE/UP/2
BS6173 and BS5440
T100916 Ref. 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G1808X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Falcon G1808X

  • Page 1 G1808X, G1838X, G1848X Fryers INSTALLATION and SERVICING INSTRUCTIONS This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations. IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation.
  • Page 2 IMPORTANT INFORMATION Warranty Policy Shortlist Warranty does not cover :- • Correcting faults caused by incorrect installation of a product. • Where an engineer cannot gain access to a site or a product. • Repeat commission visits. • Replacement of any parts where damage has been caused by misuse. •...
  • Page 3: Section 1 - Installation

    IGE/UP/2. This should not be smaller than gas inlet any combustible wall. connection. If the floor is constructed of combustible material, G1808X - Rp½ (½" BSP) then local fire requirements should be checked to ensure G1838X - Rp¾ (¾" BSP) compliance. G1848X - 2 x Rp½ (½" BSP)
  • Page 4: Section 2 - Assembly And Commissioning

    SECTION 2 - 1.8 INJECTOR SIZE 1.8.1 Natural Gas ASSEMBLY and COMMISSIONING Model Pilot Burner Cross-lighter Main Burner G1808X 0.026 2 x Ø2.38mm 2.1 ASSEMBLY The unit is packed as a complete assembly. G1838X 0.026 2 x Ø3.3mm G1848X 0.026 4 x Ø2.38mm...
  • Page 5: Section 3 - Servicing And Conversion

    SECTION 3 - 3.2.2 Removal of Pilot Burner SERVICING and CONVERSION Isolate main gas supply to unit. Disconnect pilot supply pipe compression nut and remove pipe from pilot burner. Important Withdraw injector. Undo thermocouple retaining nut and BEFORE ATTEMPTING ANY SERVICING, ENSURE remove thermocouple from pilot burner.
  • Page 6 3.6 THERMOSTATS Remove white thermostat wires on thermocouple For removal of User thermostat, refer to Section 3.7. interruptor. The safety thermostat is an EGO model. When activated, Re-assemble parts in reverse order. Ensure small this interrupts the millivolt signal from thermocouple tip compression nut is not secured before thermostat is and subsequently shuts down the gas supply in the event secured to mounting bracket inside pan.
  • Page 7: Section 4 - Spares

    SECTION 4 - SPARES When ordering spare parts, always quote unit type and serial number. This information will be found on data badge on upper panel behind door.

This manual is also suitable for:

G1838xG1848x