Problem
Solution(s)
• This timer provides an automatic 15 sec. delay
between successive circuits when programmed
to switch at the same On time. Use the Inter-
val or Pulse features to eliminate if required.
NOTE: ASTRO switching times change daily
according to changing Sunrise and Sunset.
Consider fixed times with this in mind, e.g. a
fixed Off intended to end an Astro On would
be ignored if sunset moves beyond the fixed
Off time. The fixed event should be scheduled
to occur outside the range of the Astro event,
or an Astro Pulse should be considered.
NOTE: Override intervals are not ended by
scheduled events; they can only be ended by
timing out, by power interruptions, or by
pressing the ON/OFF key.
• NOTE: Override intervals or pulses are not
ended by scheduled OFF events; they can only
be ended by timing out, by power interruptions,
or by pressing the ON/OFF key. At the
termination of an override interval or pulse, the
load may be on or off. If the override interval or
pulse was initiated via the front panel ON/OFF
key, the load will normally be off at the end of
the override interval or pulse; the load will
remain on only if an ON set point has occurred
during the override interval or pulse. If the
override interval or pulse was initiated via the
remote override connector, the circuit will
revert to its normally programmed condition at
the end of the override interval or pulse.
Timer Ignores
• Processor is "locked up". Press and release
Pushbuttons
RESET key while holding down the CLEAR key.
Release CLEAR when "reset" appears in display.
If no improvement, remove and restore AC
power and battery, then re-try.
34
Problem
Solution(s)
Difficulty in
• The two most common mistakes are forgetting
Programming
to press AM or PM after each time entry and
forgetting to select a load with the Enable
switch. You cannot program switch times
(PROGRAM) unless you select a load using the
Enable switches. Pressing the HELP key
when an error (ERR--) message appears will
explain the error and may offer
recommended action.
Override
• An interval or pulse duration must have been
Interval or Pulse previously programmed (check by pressing
Won't Start
INTVL or PULSE key in SET mode without
selecting a day) and the circuit must be
Enabled.
Override
• If an interval or pulse duration has been
Interval or Pulse programmed, the remote switch will only
Won't Stop with start the override interval or pulse. Operating
Remote Switch
it again will restart the override interval or
pulse. The interval and pulse both must be
un-programmed (Display shows dashes in
review) and the circuit's slide switch must be in
Enable position to allow remote turn off.
Interval
• Actual duration is the programmed duration ±
Override
30 seconds.
Duration Varies