Chapter 2
Switch Installation (24- and 48-Port Switches)

Box Contents

The switch getting started guide on Cisco.com describes the box contents. If any item is missing or
damaged, contact your Cisco representative or reseller for support.

Tools and Equipment

You need to supply a number-2 Phillips screwdriver to rack-mount the switch.

Verifying Switch Operation

Before you install the switch in a rack, on a wall, or on a table or shelf, you should power on the switch
and verify that the switch passes POST.
If your configuration has an RPS, connect the switch and the RPS to the same AC power source. See
Chapter 3, "Switch Installation (8-Port Switches),"
information.
When you connect the RPS to the switch, put the RPS in standby mode. Set the RPS to active mode
Note
during normal operation.
To power on the switch, connect one end of the AC power cord to the AC power connector on the switch,
and connect the other end of the power cord to an AC power outlet.
OL-7075-09
When you use shorter lengths of single-mode fiber cable, you might need to insert an inline optical
attenuator in the link to avoid overloading the receiver.
When the fiber-optic cable span is less than 15.43 miles (25 km), you should insert a 5-decibel (dB)
or 10-dB inline optical attenuator between the fiber-optic cable plant and the receiving port on the
1000BASE-ZX SFP module at each end of the link.
The operating environment must be within the ranges listed in
Specifications."
Clearance to front and rear panels meets these conditions:
You can easily read the front-panel indicators.
Access to ports is sufficient for unrestricted cabling.
The rear-panel power connector is within reach of an AC power receptacle.
Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent
lighting fixtures. Make sure the cabling is safely away from other devices that might damage the
cables.
Airflow around the switch and through the vents is unrestricted.
Temperature around the unit does not exceed 113°F (45°C).
If the switch is installed in a closed or multirack assembly, the temperature around it might be
greater than normal room temperature.
Appendix A, "Technical
and see the Cisco RPS documentation for more
Catalyst 2960 Switch Hardware Installation Guide
Verifying Switch Operation
2-5