Remote Control: Model 17005
This air purifier features a remote control handset for additional convenience. The
remote control allows you to turn the air cleaner OFF and to change the running speed
(LOW, MED, HIGH). NOTE: When a program function is running (pre-set or customized
program cycles), you may override the speed setting; the unit will continue with its
programmed function once it reaches the next programmed time.
Intelli-Check
The model 17005 series air purifier is equipped with Intelli-Check
as a convenient reminder for when to clean the LifeTime HEPA
the carbon pre-filter based on the air cleaner's hours of use and operating speed. This is
beneficial because a filter's life depends on the amount
of air and contaminants drawn through it. Each filter bar
will fill up from clean to dirty as its expected filter life
is used up. Once the bar is completely full, it is time to
check and clean/replace the appropriate filter.
• To move between the PRE-FILTER bar and the
HEPA FILTER bar, quickly press the FILTER button
(Fig. 6a).
• To RESET a filter bar that appears on the display,
press and hold the FILTER button for 5 seconds, or
until the filter bar clears to CLEAN status (Fig. 6b).
The Intelli-Check
Filter Monitors calculate the
expected pre-filter life based on an assumed average
operating time of 12 hours a day on medium speed.
Therefore, it will indicate replacement of the Pre-filter in
about 3 months. Depending upon your individual usage
(environment, hours and speed of operation), you may
need to check and replace the pre-filters more or less
frequently.
Battery Replacement: Model 17005 Series
Remote control handset: Two 1.5V AAA size batteries. Replace as needed.
Control Panel Battery backup: Replace battery with Panasonic CR 2032, 3V only. Use of
another battery may present a risk of fire or explosion. Replace when Battery Low icon
appears on viewing screen (
to prevent loss of customized programs. To replace
battery, locate battery door on control panel. Use a flat
head screwdriver to gently pry up both ends of the
battery door (Fig. 7). Carefully remove battery holder
from unit. Make sure that the (+) sign on the battery is
facing up in the battery holder before returning the new
battery to the unit. Dispose of used battery promptly.
Keep away from children. Do not disassemble and do
not dispose of in fire.
8
Filter Monitors: Model 17005
). Keep unit plugged in
while replacing battery
Filter Monitors to serve
Filter and when to replace
Fig. 6a
Fig. 6b
Fig. 7