Table 122 Read Stream Error Log - Hitachi CinemaStar P7K500 Specifications

Hitachi cinemastar p7k500: specifications
Table of Contents

Advertisement

10.19.5 Read Stream Error log
Table 121 defines the format of the Read Stream Error log. Entries are placed into the Read Stream Error log
only when the SE bit is set to one in the Status Register. The 512 bytes returned shall contain a maximum of
31 error entries. The Read Stream Error Count shall contain the total number of Read Stream Errors detected
since the last successful completion of the Read Log Ext command with LBA Low register set to 22h. This
error count may be greater than 31, but only the most recent 31 errors are represented by entries in the log. If
the Read Stream Error Count reaches the maximum value that can be represented after the next error is
detected the Read Stream Error Count shall remain at the maximum value. After successful completion of a
Read Log Ext command with the LBA Low Register set to 22h, the Read Stream Error Log shall be reset to a
power-on or hardware reset condition, with the Error Log Index and Read Stream Error Count cleared to zero.
The Read Stream Error Log is not preserved across power cycles and hardware reset.
Description
Structure Version
Error Log Index
Read Stream Error Log Count
Reserved
Read Stream Error Log Entry #1
Read Stream Error Log Entry #2
...
Read Stream Error Log Entry #31

Table 122 Read Stream Error Log

HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1)
Bytes
165
Offset
1
00h
1
01h
2
02h
12
04h
16
10h
16
20h
16
1F0h
512