5. Trouble-Shooting

5.1 Operation

The Multi Function ON/OFF button is pressed but the PROFI CHARGER does not power-up.
a)
Make sure the AC power cord is completely inserted into the AC outlet.
b)
Make sure the AC outlet is live (check fuse or circuit breaker).
c)
Check the AC power cord for damage.
d)
Check the fuses on the outside of the charger.

5.2 Error-Codes

Through the red STATUS LED's error codes can be transmitted, the selected green function LED will blink
at the same with the same frequency.
Code
Description
01
Reverse polarity
02
Connection problem
03
Non 12V battery connected
04
Battery voltage too low (< 5,5 V)
05
Charge voltage problem, no increase
06
Charge current problem, no increase
07
Too low charge current
08
Internal current failure
09
Internal voltage failure
10
Internal charger
temperature too high
Sample:
This blink rate means error code 3 (non 12V battery connected).

5.3 Fuses

On the outside of the charger you find 1 fuse.
Action
Correct clamps, red to plus and black to minus pole
Correct connection and restart charge sequence
Connect correctly to 12 V
Battery deeply discharged,
consider replacement battery might be damaged
Consider battery replacement
Battery replacement recommended
Battery replacement recommended
Switch off unit
(press ON/OFF button for 2 seconds) and try again.
If problem is consistent call for service.
Switch off unit (press ON/OFF button for 2 seconds).
Switch on again and leave the fan running. If fan is not
running call for service.