Advertisement

Quick Links

PSEN ma1.3p-20
}
PSEN sensor technology
Operating Manual-22147-EN-05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSEN ma1.3p-20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pilz PSEN ma1.3p-20

  • Page 1 PSEN ma1.3p-20 PSEN sensor technology Operating Manual-22147-EN-05...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Requirements and connection to evaluation devices ............Installation ..........................Adjustment ..........................Periodic test ........................... Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Order reference ........................System ............................Accessories ..........................EC declaration of conformity ....................Operating Manual PSEN ma1.3p-20 22147-EN-05...
  • Page 4: Introduction

    PSEN ma1.3p-20 Introduction Validity of documentation This documentation is valid for the product PSEN ma1.3p-20. It is valid until new document- ation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    In order to achieve the re- quired safety level for the overall plant/machine, define the safety requirements for the plant/machine and then define how these must be implemented from a technical and organ- isational standpoint. Operating Manual PSEN ma1.3p-20 22147-EN-05...
  • Page 6: Use Of Qualified Personnel

    – If spare actuators are used, these must be installed as described in Installation [ 15]. – If the original actuators are replaced with substitute actuators, the ori- ginal actuators must be destroyed before disposal. Operating Manual PSEN ma1.3p-20 22147-EN-05...
  • Page 7: Unit Features

    If the actuator is within the response range (safety gate closed), the safety contacts and the auxiliary contact on the safety switch will be closed and the LED will light. Operate the PSEN ma1.3p-20 in conjunction with the following components: Actuator PSEN ma1.3-08 or actuator PSEN ma1.3-12 (see...
  • Page 8: Block Diagram

    Block diagram Safety switch Actuator Magnet Operating distances (mm) omin Legend Assured operating distance Min. operating distance omin Assured release distance The offset-independent values for the switching distances are included in the Technical details [ 20]. Operating Manual PSEN ma1.3p-20 22147-EN-05...
  • Page 9: Lateral And Vertical Offset

    Lateral and vertical offset Actuator PSEN ma1.3-08 Legend [1] Lateral offset [2] Vertical offset [3] Sensing faces Assured operating distance S in mm Lateral offset Vertical offset The stated values are valid at a temperature of 20 °C. Operating Manual PSEN ma1.3p-20 22147-EN-05...
  • Page 10 The stated values are valid at a temperature of 20 °C. Negative vertical offset, not permitted Fig.: Safety switch and square actuator - side view Legend [1] Sensing face PSEN ma1.3-12 [2] Positive vertical offset, permitted [3] Negative vertical offset, not permitted Operating Manual PSEN ma1.3p-20 | 10 22147-EN-05...
  • Page 11: Wiring

    Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an unoperated condition. Assignment of pink...
  • Page 12: Requirements And Connection To Evaluation Devices

    PNOZmulti units – may not be used for safety circuits Requirements and connection to evaluation devices For use of PSEN ma1.3p-20 in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma1.3p-20 either with a certified Pilz evaluation device...
  • Page 13 [ of PSEN ma1.3p-20 – Always comply with the max. switching current safety contacts of PSEN ma1.3p-20. Outputs at the evaluation device must only be switched on again when both reed con- tacts at the safety switch have been opened and closed (partial operation lock)
  • Page 14 PSEN ma1.3p-20 Examples for connection to Pilz evaluation devices: PSENmag PNOZ s3 White Yellow Pink Green PNOZmulti PSENmag White Yellow Pink Green Legend Input OSSD Input OSSD T0, T1 Test pulse outputs Operating Manual PSEN ma1.3p-20 | 14 22147-EN-05...
  • Page 15: Installation

    Possible loss of the safety function by changing the release distance with non-flush installation Installing the safety switch non-flush within electrically or magnetically con- ductive material, the value for the assured release distance S can change. – Check the assured release distance S Operating Manual PSEN ma1.3p-20 | 15 22147-EN-05...
  • Page 16 Protect the safety switch and actuator from UV light or direct sunlight. The protection type (see Technical details [ 20]) can only be achieved by using the Pilz connection leads available as an accessory. Operating Manual PSEN ma1.3p-20 | 16 22147-EN-05...
  • Page 17 Sensing face Attach the actuator using 2 M12 hexagonal nuts with special threads. Note the max. torque setting (see Technical details [ 20]). Operating Manual PSEN ma1.3p-20 | 17 22147-EN-05...
  • Page 18: Adjustment

    Periodic test Carry out a monthly function test on the safety switch and actuator. Always test the function with a connected evaluation device. The safety function may only be checked by qualified personnel. Operating Manual PSEN ma1.3p-20 | 18 22147-EN-05...
  • Page 19: Dimensions In Mm

    PSEN ma1.3p-20 Dimensions in mm Safety switch 26,8 42,6 12,5 33,9 59,1 200 ±10 Actuator PSEN ma1.3-08 Actuator PSEN ma1.3-12 2xø4,5 Fig.: Actuator holder Operating Manual PSEN ma1.3p-20 | 19 22147-EN-05...
  • Page 20: Technical Details

    EN 60947-5-3 Vibration In accordance with the standard EN 60947-5-2 EN 60947-5-2 Frequency 10 - 55 Hz 10 - 55 Hz Amplitude 1 mm 1 mm Shock stress Acceleration Duration 11 ms 11 ms Operating Manual PSEN ma1.3p-20 | 20 22147-EN-05...
  • Page 21 25 mm 25 mm Weight of safety switch 20 g 20 g Weight of actuator 11 g 11 g Weight 30 g 30 g Where standards are undated, the 2015-09 latest editions shall apply. Operating Manual PSEN ma1.3p-20 | 21 22147-EN-05...
  • Page 22: Safety Characteristic Data

    PSEN cable M8-8sf, 10 m M 8, 8-pin fe- 533 152 male con- nector, straight PSEN cable M8-8sf, 20 m M 8, 8-pin fe- 533 153 male con- nector, straight Operating Manual PSEN ma1.3p-20 | 22 22147-EN-05...
  • Page 23: Ec Declaration Of Conformity

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany Operating Manual PSEN ma1.3p-20...
  • Page 24 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...