Fault
Appliance door opens too
wide at the end of the pro-
gramme.
Error code / Fault display / Signal
Fault
E:2130 lights up.
E:2060 lights up.
E:3000 lights up.
E:3100 lights up.
E:3400 lights up.
E:3200 or indicator for wa-
ter supply lights up.
1
Depending on the appliance specifications
Cause
Door is not correctly adjus-
ted.
Wrong screws used to ad-
just the door gap.
Cause
Intake opening of Zeolith
container is covered by
items of tableware.
Appliance has detected cal-
cified heating element.
Water protection system is
activated.
Water protection system is
activated.
Water is continuously run-
ning into the appliance.
Supply hose is kinked.
Water tap is turned off.
Water tap is jammed or
furred up.
Troubleshooting en
Troubleshooting
Adjust the appliance door as de-
▶
scribed in the installation instruc-
tions.
The door gap must be at least
70 mm - 100 mm.
Use size 4X30 bolts to adjust the
▶
door gap.
The bolts are included in the scope
of supply.
If you use bolts that are too long,
this can deactivate the function of
automatic door opening.
Troubleshooting
Re-arrange the tableware in the ap-
▶
pliance so the "Intake opening of
the Zeolith container " → Page 15
is no longer obstructed.
Descale the appliance.
1.
Operate the appliance with the wa-
2.
ter softening system.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 60.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 60.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 60.
Install the supply hose without
▶
kinks.
Turn on the water tap.
▶
Turn on the water tap.
▶
The flow rate must be at least 10 l/
min when the water supply is open.
1
47