Installing the Redundant Power Supply Adapter Plate

Step 3
Figure 6
Step 4
Installing the Redundant Power Supply Adapter Plate
Take these steps to install the Cisco RPS Adapter Plate:
Step 1
Figure 7
Step 2
Figure 8
LINK
8 Installing the Cisco RPS Adapter Plate in Cisco 2600 Series Routers
Slide the power supply forward slightly in the chassis. This disengages the built-in hooks
that help secure the power supply to the chassis. (See Figure 6.)
Removing the Power Supply
AC power supply
Place the removed screw and power supply in an antistatic bag.
Place the router so that the rear panel is facing you. (See Figure 7.)
Cisco 2600 Series Rear Panel (Cisco 2610 Shown)
Cisco 2610
SERIAL 1
SERIAL 0
CONN
SEE MANUAL BEFORE INSTALLATION
W1
Ethernet 0/0
10BaseT
port (RJ-45)
Attach the DC power rating label over the ratings on the rear panel of the router.
(See Figure 8.)
Attaching the DC Power Rating Label
SERI AL 1
SERI AL 0
CONN
SEE MANU AL BEFO RE INSTA LLAT
ION
ACT
ETH ERN ET 0
CON SOL E
Fan
Cisco 2610
SERIAL 1
100-240V– 1A
50/60 Hz 47 W
WIC
SERIAL 0
CONN
2A/S
CONN
WIC
CONN
2T
SEE MANUAL BEFORE INSTALLATION
W0
LINK
ETHERNET 0 ACT
CONSOLE
AUX
Auxiliary port
(RJ-45)
Console
port (RJ-45)
Label
Cis co 26 10
WIC
CONN
2T
W0
AUX

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents