Cisco SCE 2000 4/8xFE Quick Start Manual page 33

Cisco systems sce 2000 platform quick start guide
Hide thumbs Also See for SCE 2000 4/8xFE:
Table of Contents

Advertisement

To specify link-0, press Enter.
To specify link-1, type 1 and press Enter.
Enter Physically connected link:
0- link-0
1- link-1
Enter your choice [0]:
Step 5
Specify the SCE 2000 priority.
To specify Primary, press Enter.
To specify Secondary, type 2 and press Enter.
Enter SCE 2000 priority:
1- primary
2- secondary
Enter your choice [1]:
Step 6
Specify the On-failure link behavior.
To specify Bypass, press Enter.
To specify Cutoff, type 2 and press Enter.
Enter On-failure behavior:
1- bypass
2- cutoff
Enter your choice [1]:
Specify the status of the SCE 2000 after abnormal boot.
Step 7
To specify Operational status after abnormal boot, press Enter.
To specify Not-Operational status after abnormal boot, type 2 and press Enter.
Enter admin status of the SCE after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]:
The following examples present the procedure for configuring the topology-related parameters for various topologies.
E
1:
XAMPLE
Following is a sample topology configuration for a non-redundant topology using an external switch, that is, a single SCE
2000 connected in receive-only connection mode, to one or two FE links
Would you like to enter the Topology configuration menu? [no]: y
Would you like to enter the Topology configuration menu? [no]: y
Enter Connection mode:
1- inline
2- receive-only
Enter your choice [1]: 2
Is this a cascade deployment? [no]: no
Enter admin status of the SCE after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]: 1
Data collection for the system configuration is completed.
All other parameter values are automatically assigned by the system.
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sce 1000

Table of Contents