Download Print this page

Safety Precautions - Haier AD182AMBIA Operation And Installation Manual

Duct type air conditioner
Hide thumbs

Advertisement

SAFETY PRECAUTIONS

The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
Heating
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided. The power cable should be
H07RN-F 3G4.0mm
All the cables shall have got the European authentication certificate. During installa-
tion, when the connecting cables break off, it must be assured that the grouding wire is
the last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its
two contacts should be no less 3mm.
7. The indoor unit installation height is at least 2.5m.
8. The power supply connects from the outdoor side.
DB C
Indoor
WB C
DB C
outdoor
WB C
Indoor
DB C
WB C
DB C
outdoor
WB C
2
and the connecting cable should be H05RN-F 4G 0.75mm
Rated Maximum Minimum
27
32
19
23
35
43
24
26
20
27
14.5
--
7
24
6
18
5
18
14
-5
--
15
--
-7
--
2
.

Advertisement

loading

  Also See for Haier AD182AMBIA

  Related Manuals for Haier AD182AMBIA

This manual is also suitable for:

Ad242ambiaAu182afbjaAu242ahbia