Installation Procedures

SELECTING THE MOUNTING POSITION
Install at a place that can withstand the weight of the
indoor and outdoor units and install positively so that
the units will not topple or fall.
(1)Do not install where there is the danger of com-
bustible gas leakage.
(2) Do not install near heat sources.
(3) If children under 10 years old may approach
the unit, take preventive measures so that they
cannot reach the unit.
Decide the mounting position with the customer as follows:
1. INDOOR UNIT
(1) Install the indoor unit level on a strong wall, floor,
ceiling which is not subject to vibration.
(2) The inlet and outlet ports should not be obstructed:
the air should be able to blow all over the room.
(3) Install the unit near an electric outlet or special
branch circuit.
(4) Do not install the unit where it will be exposed to
direct sunlight.
(5) Install the unit where connection to the outdoor
unit is easy.
(6) Install the unit where the drain pipe can be easily
installed.
(7) Take servicing, etc. into consideration and leave the
spaces shown in Fig.A. Also install the unit where
the filter can be removed.
Floor console
Fig.A
Left
30 cm
or more
WARNING
CAUTION
may be difference
1.5m
Right
1.5m
30 cm
or more
Under ceiling
Left
30 cm
or more
Outdoor unit
12
Indoor unit
1.5m
Ceiling
2 cm
or more
12.7mm dia.
Indoor unit
Right
6.35mm dia