ElectrIQ eiQSLIM100TOUCH User Manual page 9

Table of Contents

Advertisement

5. The 2 air flaps should now be
installed, as access is easier
before the unit is wall mounted.
The 2 flaps should be carefully
installed to the top of the hood
unit, bending them slightly so the
lugs at each end locate into the
holes in the outlet vent. When
the unit is in operation the flaps
pivot upwards to allow airflow.
Please note: the small
spindles/lugs at each end of
each flap locate into the holes on
the housing, not the grooves
above them. Once the flaps are
installed the expansion pipe can
be attached to the hood body.
7. Install the Plate 1 on to the outer chimney
section using 2 screws (4mm x 8mm), making
sure the outer chimney is free to slide. Then
place the chimney onto the top of the hood. If
externally venting, the expansion pipe should
be routed in its final position.
6. Hang the hood onto the mounting
bracket, and then secure to the wall using
the supplied 4mm x 30mm screws and wall
plugs.
8