Hewlett–Packard Preliminary and Confidential
From the above power budget the following power supply specifications were established. The
power supply specifications are still under negotiation. At the present time, agreement has been
reached on the following specifications.

Air Flow

The B132L/B160L is cooled by forced convection using two 92mm DC fans. The direction of
airflow is from the front of the workstation to the back. Fan speeds can be adjusted for ambient
temperature. The disk bay houses an additional fan to cool the mass storage devices. The disk bay
fan is mounted to the bottom of the disk bay under the rear disk drive. The disk bay fan pulls air into
the disk bay under the front disk, over the rear disk, and out the main air flow stream.
Figure 3–2. Air Flow