2.23 ~AAI

Description:
This command enables "Soft INIT" function which cause the
module to temporarily enter initialization mode. The "~AATnn"
(See Section 2.26) command can then be used to set the
duration of the "Soft INIT" mode. During that time, can be
changed the BaudRate and checksum of the module by using
the "%AANNTTCCFF" command (See Section 2.1).
Syntax:
~AAI[CHKSUM](CR)
~
Delimiter character
AA
Address of the module in hexadecimal format (00
to FF)
I
Command to enable the Soft INIT function
Response:
Valid Command:
Invalid Command:
!
Delimiter for a valid command
?
Delimiter for an invalid command
AA
Address of the module in hexadecimal format (00
to FF)
There will be no response if the command syntax is incorrect,
there is a communication error, or there is no module with the
specified address.
!AA[CHKSUM](CR)
?AA[CHKSUM](CR)