Related Parameters - YASKAWA SI-W3 Installation Manual

Hide thumbs Also See for SI-W3:
Table of Contents

Advertisement

6 Related Parameters

6
Related Parameters
The following parameters are used to set up the drive for operation with the option.
Confirm proper setting of the parameters in
communications.
No.
(Addr.
Name
Hex)
b1-01
Frequency Reference
(180)
Selection 1
b1-02
Run Command
(181)
Selection 1
F6-01
Communications Error
(3A2)
Operation Selection
External Fault from
F6-02
Comm. Option
(3A3)
Detection Selection
External Fault from
F6-03
Comm. Option
(3A4)
Operation Selection
F6-06
Torque Reference/
(3A7)
Torque Limit Selection
from Comm. Option
<2>
Multi-Step Speed
Enable/Disable
F6-07
Selection when
(3A8)
NefRef/ComRef is
Selected
24
Table 4
Table 4 Related Parameters
Description
Selects the frequency reference input source
0: Digital Operator - Digital preset speed d1-01 to d1-17
1: Terminals - Analog input terminal A1 or A2
2: MEMOBUS/Modbus communications
3: Option
4: Pulse Input (Terminal RP)
Selects the run command input source
0: Digital Operator - RUN and STOP keys
1: Digital input terminals S
2: MEMOBUS/Modbus communications
3: Option
Determines drive response after a bUS error during
communications with the option
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
<1>
Sets the condition for external fault detection (EF0)
0: Always detected
1: Detected only during operation
Determines drive response for external fault input (EF0)
detection during LONWORKS communication
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
<1>
0: Torque reference / torque limit via network
communications are disabled.
1: Torque reference / torque limit via network
communications are enabled.
0: Multi-step speed reference disabled (F7 functionality)
1: Multi-step speed reference allowed (V7 functionality)
YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide
before starting network
<3>
Values
Default: 1
Range: 0 to 4
(Set to 3 for
LONWORKS
only)
Default: 1
Range: 0 to 3
(Set to 3 for
LONWORKS
only)
Default: 1
Range: 0 to 3
Default: 0
Range: 0, 1
Default: 1
Range: 0 to 3
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1