2.
Orient the SFP with the appropriate port. See
Figure 7 Installing an SFP
Table 13 SFP components
Item
1
2
3.
Insert the SFP into the port until you hear a click.
4.
Close the bail.

Diagnostic tests

In addition to POST, Fabric OS includes diagnostic tests to help troubleshoot the hardware and the
firmware including tests of internal connections and circuitry, fixed media, and the transceivers and
cables in use.
Initiate diagnostic tests with the command line, using a Telnet session or a terminal setup with a serial
connection to the switch. Some tests require the ports to be connected by external cables to allow
diagnostics to verify the serializer/deserializer interface, transceiver, and cable. For information on
available diagnostic tests, enter diagHelp.
All diagnostic tests are run at link speeds of 1 Gbps, 2 Gbps, 4 Gbps, and 8 Gbps.
CAUTION:
Diagnostic tests can temporarily lock the transmit and receive speed of the links during diagnostic testing.
For information about specific diagnostic tests, refer to the latest version of the HP StorageWorks Fabric
OS administrator guide, or enter help followed by the name of the diagnostic test.

Powering on and off

8Gb SAN Switch power is provided by the enclosure. The 8Gb SAN Switch runs POST by default each
time power to the enclosure is turned on. The POST process can last as long as three minutes.
To remove power from the switch, remove the 8Gb SAN Switch from the enclosure interconnect bay.
Figure 7
scale: 3/8" = 1"
2 3
2 2
2 1
2 0
1 9
1 8
1 7
!
2
Description
bail
SFP
Brocade 8Gb SAN Switch for HP BladeSystem c-Class
and
Table
13.
0
1
26479a
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 8gb san

Table of Contents