Verify Correct Operation; Led Behavior - HP ProCurve J8161A Installation And Getting Started Manual

External power supplies
Table of Contents

Advertisement

Installing and Connecting the HP 600/610 External Power Supplies
Installation Procedures

6. Verify Correct Operation

When the HP 600 RPS/EPS or HP 610 EPS is mounted in its location and
powered on, you should first verify that it is working properly by checking the
unit's LEDs.
Check the LEDs on the unit as described below.
Device Connected
Power Status
Fan/Temp
Power
Status
Fan/Temp Status flash = Temperature too high
Fault
Fan/Temp Status + Fault flash = Fan failure
Power and
Fan/Temp Status LED
Fault LEDs
HP ProCurve
610 EPS
J8169A
Power
Internal Power Status
Fan/Temp Status
Fault
Fan/Temp Status flash = Temperature too high
Fan/Temp Status + Fault flash = Fan failure
Power and
Fan/Temp
Fault LEDs
Status LED
When the unit is powered on, it performs its diagnostic self test. The self test
takes approximately 5 seconds to complete.

LED Behavior:

2-14
EPS port LEDs
EPS Port Status
E2
E1
EPS Backup Power port LEDs
EPS Backup Power Ports Status
In Ready
Out Ready
Internal Power
Status LED
During the self test:
Initially, all the unit and port LEDs are on and stay on for most of the
duration of the self test.
Most of the LEDs go off and then may come on again during phases
of the self test.
When the self test completes successfully:
The Power, Internal Power Status, and Fan/Temp Status LEDs remain on.
The Fault LED goes off.
RPS port LEDs
RPS Port Status
Device Connected
R6
R5
R4
Power Status
EPS port LEDs
EPS Ports Pair A
( 408 W total for PoE applications)
A1
EPS A1
EPS A2
HP 600 RPS/EPS
R3
R2
R1
HP 610 EPS
Device
A2
Connected
Power
Status
EPS Ports: 50 V
8.3 A max per port pa