20____ Doc # 01-04-025C Year of Manufacture: Original Instructions E200 LED Exposing Unit Assembly and Operation Instructions E2-2128 Vastex International, Inc. 1032 N. Irving St. Allentown, Pa. 18109 USA Contents Page# Phone# 610 434-6004 Fax# 610 434-6607 Introduction, Machine Specifications ...
Thank you for purchasing your printing equipment form Vastex International Inc. Vastex has been designing and building printing equipment since 1960. We have the knowledge and experience, and are supplying the printing industry with quality equipment at an affordable price.
Safety Information Read this manual before assembling and operating your exposing unit. Safety: The operator should read and understand this manual before operating this equipment. Store manual and safety information near equipment for easy access to operators. Never leave equipment unattended while in operation. ...
Assembly Getting started: Your Exposing Unit has been fully assembled and tested in our factory. Both lid lifting cylinders have been removed from their upper mounting stud and secured to the side of the cabinet. Be careful not to damage the rubber vacuum blanket when removing the Exposing Unit from it's crating.
Operation Overview: Your Exposing Unit is equipped with LED Lights, vacuum timer, exposure timer, vacuum pump, and separate switches for main power and exposure cycle start. The vacuum pump draws the air out from between the blanket and glass. This flattens the coated screen and positive to the glass making for a sharper exposed image.
Maintenance Wear gloves when handling the glass. Do Not allow objects to contact Glass is tempered and although strong, the LED light lens. can shatter if the edges are subjected to an impact. Glass Removal / Installation There are three glass retainers. One on each side to square the glass to the rear seal and Shown is the larger E2000 LED exposure unit.
If this seal is not fasteners. contacting the glass it will be necessary to adjust the lid lower. Proceed as follows. 7) Contact Vastex for technical support if these (Pictures below for reference) steps fail to resolve the problem. Lid Adjustment Bolts...
Page 8
Troubleshooting Light Bar Replacement / Installation Note: It is important to wear dark shaded and UV rated eye protection when testing LED Lights. Do Not allow objects to contact the LED light lens. 1) 1) Inspection of LED light Bars. Lift the lid and override the safety switch on the left side of the cabinet by depressing with your finger or a pencil.
example would be that pure coat the squeegee side once over the Emulsion information photopolymer emulsions are available entire screen. Coat again the squeegee for the screen printer in very high solids content with low side on only two thirds of the screen, viscosity.
Page 10
(emulsion up) on a hard flat surface. pressure stroke with a soft squeegee. (Fig. 7) (Fig. 9) The use of newsprint on your work surface will help with clean up. Fig. 4 Surface smoothness can affect your substrate to stencil gasket. The lower Rz numbers will be produced only by machine coating or film products.
Page 12
The defective part or parts will be repaired or replaced at the discretion of Vastex International, Inc. If the equipment in question is less than one (1) year old, it will be shipped to the customer at no charge, with an RGA issued by Vastex for the defective part. The defective part must be shipped back to Vastex freight prepaid within 30 days or the account will be billed.
Need help?
Do you have a question about the E2-2128 and is the answer not in the manual?
Questions and answers