SECTION ONE GENERAL INFORMATION The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation. PARTS INCLUDED - piR Sensor unit. - instruction manual.
SECTION THREE INSTALLATION After choosing a suitable location (see previous section) install the unit as follows: *** IMPORTANT *** Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. Remove the wiring box cover by unscrewing the retaining screw (fig F) and with a screwdriver gently push down and ease out.
Page 4
TOp VieW 200º SiDe VieW 2.5m Less sensitive More sensitive...
Page 5
place this edge against wall and use diagram to estimate incoming cable length 75mm (3”) NOT TO SCALE 25mm (1”) inCOMinG WiRe TeMpLATe Use this diagram to estimate incoming cable length...
CONNECTION DIAGRAM Isolation Switch Load Mains Supply SECTION FOUR OPERATION AND TESTING WALK TEST PROCEDURE The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in the required direction. (note diagram B) The unit can be set up in daylight or at night.
Page 7
The TiMe setting controls how long the unit remains illuminated following activation and after all motion ceases. (See diagram G. the time adjustment knob is indicated by the "Clock" symbol). The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approx.
HOLIDAY MODE Switch the internal wall switch/circuit breaker 3 times (off/on off/on off/on) within 2 seconds. A single flashing red LeD at the top of the sensor head indicates Holiday Mode. The unit will now illuminate for a user defined time between 1 and 8 hours. The time can be set by rotating the centre adjustment knob as required.
Page 9
Time Dusk/Dawn Holiday Mode Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection...
SECTION SIX TROUBLESHOOTING GUIDE PROBLEM SOLUTION The unit may be suffering from false activation. Cover the o Lamp stays On all the time sensor lens completely with a thick cloth. This will prevent the sensor from "seeing" anything. if the unit now night.
Page 11
PROBLEM SOLUTION o Unit activates during the The level of ambient light in the area may be too dark for daytime the current DUSK setting. During daylight, adjust the DUSK control slightly anti-clockwise. When the lamp load extinguishes, enter the detection area. if the piR still activates, the setting is still too high.
Page 12
For assistance with the product please contact:- HeLpLine 020-8450-0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Ltd. Victory park, 400 edgware Road, London nW2 6nD Tel: 020-8452-1112 or email csc@timeguard.com Group company 67-058-308 (iss.1)