Direct Current
Range
Resolution
2 mA
20 mA
200 mA
20 A
Burden voltage:
Maximum voltage: 250 volts maximum when measuring current
Alternating Current (50 Hz – 400 Hz)
Range
Resolution
2 mA
20 mA
200 mA
20 A
Burden voltage:
Maximum voltage: 250 volts maximum when measuring current
Resistance
Range
Resolution
200
2 K
20 K
200 K
2 M
20 M
Open circuit voltage: 3 VDC in the 200
1 A
+/– (0.8% + 2 digits)
10 A
100 A
+/– (1.0% + 2 digits)
10 mA
+/– (1.2% + 5 digits)
500 mV maximum in the 20 A range
350 mV maximum in all other ranges
1 A
10 A
+/– (1.0% + 5 digits)
100 A
10 mA
+/– (2.0% + 5 digits)
500 mV maximum in the 20 A range
350 mV maximum in all other ranges
0.1
1
10
+/– (0.8% + 3 digits)
100
1 K
10 K
+/– (1.2% + 5 digits)
0.3 VDC in all other ranges
Accuracy
Accuracy
Accuracy
range
93-604 Multimeter
Overload Protection
200mA/250V fuse
20A/250V fuse
Overload Protection
200mA/250V fuse
20A/250V fuse
Overload Protection
500 VDC/VAC RMS