Mounting The Radiator Controller - Honeywell THR0924 Manual

Wireless radiator controller
Table of Contents

Advertisement

Interrupting the radio test
The radio test is terminated automatically after approx.
10 minutes.
– or –
fSelect
using the adjustment dial and confirm
exit
with the
button.
Radio communication error
If the exclamation mark
flash during normal operation, an error has occurred
during radio communication.
• The room setpoint temperature of the HR92 radiator
controller is changed automatically to 20 °C.
fRestore radio communication to the central operating
device, see Section 7.

Mounting the radiator controller

The radiator controller can be mounted on all common
thermostatic valves with an M30 x 1.5 connection
without draining system.
Prevent damage to the radiator controller
through humidity and moisture!
f Mount the radiator controller indoors only.
WARNING
f Protect the radiator controller against
humidity, moisture, dust, direct sunlight or
exposure to excessive heat.
Removing the old thermostat head
1.
1. Turn the old thermostat head anti-clockwise until it
stops and loosen the mounting ring.
2. Remove the old thermostat head from the radiator
valve.
and the radio symbol
2.
Selecting the adapter
The radiator controller fits on common radiator valves
of the type M30 x 1.5. Adapters are required for some
valve types.
1. Check whether an adapter is required and, if
necessary, select the appropriate adapter.
Brand
Honeywell-
Braukmann,
MNG, Heimeier,
Oventrop valves
M30 x 1.5
Danfoss RA
Danfoss RAV
Danfoss RAVL
* can be ordered under EVA1-Danfoss
2. Slide the adapter onto the radiator valve and turn it
until you feel it click into place.
3. If necessary, screw the adapter tight with a screw.
5
Illustration
Adapter
Not
required
Supplied
*
*