induction cooKtoP inStALLAtion inStRuctionS
if the cable from appliance is equipped with 4 wires:
Where local codes permit connecting the
appliance-grounding conductor (wire) to the
neutral (white) wire (see figure 5):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box,
connect appliance and power supply cable wires as
shown in figure 5.
Cable from Power Supply
White Wire
(Neutral)
Red
Wires
Ground Wire
(Bare or Green
Wire)
Cable from appliance
Figure 5
3-WIRE GROUNDED JUNCTION BOX
This appliance is manufactured
with a white neutral power supply and a frame
connected copper wire. The frame is grounded
by connection of grounding lead to neutral lead
at the termination of the conduit, if used in USA,
in a new branch circuit installation (1996 NEC),
mobile home, recreational vehicles, where local
code do not permit grounding trough the neutral
(white) wire or in Canada, disconnect the white
and green lead from each other and use ground
lead to ground unit in accordance with local codes,
connect neutral lead to branch circuit-neutral
conductor in usual manner see Figure 6. If your
appliance is to be connected to a 3 wire grounded
junction box (US only), where local code permit
connecting the appliance-grounding conductor to
the neutral (white) see Figure 5.
Black
Wires
Junction
Box
White Wire
(Neutral)
U.L.-Listed Conduit
Connector (or CSA listed)
If cooktop is used in a new branch circuit
installation (1996 NEC), mobile home, recreational
vehicle, or where local codes DO NOT permit
grounding through the neutral (white) wire (see
figure 6):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 6.
Cable from Power Supply
Ground
Wire
Red
Wires
Ground Wire
(Bare or
Green Wire)
Junction Box
Cable from appliance
4-WIRE GROUNDED JUNCTION BOX
If connecting to a 4-wire power
WARninG
supply cable electrical system, the appliance frame
connected ground wire MUST NOT be connected
to the neutral wire of the 4-wire electrical system.
NOTE TO ELECTRICIAN: The armored cable leads
supplied with the appliance are UL and CSA-recognized
for connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring.
The current carrying capacity of the conductor is
governed by the temperature rating of the insulation
around the wire, rather than the wire gauge alone.
5
White
Wires
Black
Wires
U.L.-Listed Conduit
Connector (or CSA listed)
Figure 6