Rgb Settings; Color Grayscale Linearity - Acer AL2002 Service Manual

Hide thumbs Also See for AL2002:
Table of Contents

Advertisement

6.4. Vibration Test Procedure
6.4.1. Vibration System. Perform in accordance with Liteon Spec.
6.4.2. Fixturing. The packaged product shall be secured to the vibration table to prevent the package from moving off
the vibration surface during test.
6.4.3. Test Axes. The packaged product shall undergo random profile vibration on all six (6) surfaces for a duration of
30 minutes per surface.
6.4.4. Random Vibration Spectrum. The total random vibration spectrum energy shall be 1.15 Grms and follow
spectrum specified below.
Random Vibration Spectrum Break Points
6.4.5. Acceptance Criteria. The package and its contents should be inspected and evaluated for failure against the
Acceptance Criteria. Ref. Section 4.0 Packaged Product Testing.
7.

RGB settings

The red, green and blue areas shall be measured at a digital input signal full white square pattern at 1680x1050,
fH=65.3kHz/fV=60Hz mode with default color temperature setting (Normal Preset = 6500K). The u´ and v´ co-ordinates for
R, G and B shall be setting as follows:
Red
Green u´
Blue
8.

Color grayscale linearity

The co-ordinates of color grayscale shall be measured at a digital input signal full grayscale square pattern at 640x480,
fH=31.5 kHz/fV=60Hz mode with default color temperature setting (Normal Preset = 6500K). The measured u´ and v´
co-ordinates at grayscale 255,225,195,165,135,105 should meet the spec. as follows :
Δu´v´= ((u´max–u´min)² + (v´max–v´min)²)½
Frequency (Hz)
1
4
100
200
0.411, v´
0.503
0.140, v´
0.548
0.200, v´
0.224
0.02
2
PSD , G
/Hz
0.0001
0.01
0.01
0.001
17
Go to cover page

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al2002w-dual

Table of Contents