Note 4) After stabilizing and leaving the panel alone at a given temperature for 30 min, the
measurement should be executed .Measurement should be executed n a stable,
windless ,and dark room.30 min after lighting the back-light. This should be
measured in the center of screen. Dual lamp current :13.0mA(6.5mA x2)(Refer to the
note(1) in the page 14 for more information ).
Environment condition :Ta=25 2 C
Optical characteristics measurement setup