ASSEMBLY
WARNING
charger specified for the battery. For specific
charging instructions, read the operator's
manual supplied with your charger and battery.
ventilated area, and work with approved safety
equipment, such as those dust masks that are
specially designed to filter out microscopic particles.
Inserting/Removing the Battery
WARNING
pack before changing or removing acces-
sories. Only use accessories specifically
recommended for this tool. Others may be
hazardous.
To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
To insert the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
CAUTION
To avoid damage to the tool,
do not operate the tool without the retaing
pin fully inserted. Damage to the cylinder
may occur.
*Milwaukee jaw sold separately
Recharge only with the
Always remove battery

OPERATION

WARNING
pack before changing or removing acces-
sories. Only use accessories specifically
recommended for this tool. Others may be
hazardous.
WARNING
wear safety goggles or glasses with side
shields.
Inserting/Removing the Crimping Head
1. Pull out the retaining pin.
2. Insert the crimping head.
3. Push in the retaining pin (1).
Pressing
• Before beginning a press, inspect the jaw assembly
for cracks or other damage. Do not use a damaged
jaw assembly. Return damaged jaw assembly to the
store where the product was originally purchased or
one of our authorised MILWAUKEE® FORCELOGIC™
service centres.
• Before beginning a press, check the fuel gauge to deter-
mine whether the battery charge is sufficient to complete
the pressing operation.
• The tool will turn off
automatically after 30
minutes of no use.
• Inspect and discard
w o r k p i e c e s w i t h
cracks or wear before
use. Materials may
crack or shatter.
1. Turn the tool ON by
quickly pressing and
releasing the start
button.
2. Open the jaws and
place around the fit-
ting.
3. Hold tool securely.
Press and hold the
start button. The
green LED will go
out.
4. The automatic press
cycle begins. Re-
lease the start button and continue to hold the tool
securely.
5. When the press cycle is complete the tool will switch
off and the green LED will light.
6. To cancel the automatic press cycle, press and hold
the release button. Hold tool securely until jaws open
and the tool turns off.
7. If the tool is in use for 30 minutes continuously (e.g.,
on a manufacturing fixture), allow the tool to cool down
for at least 15 minutes before continuing. Under normal
use (e.g., plumbing/mechanical) press freely and pay
attention to the LED indicators (see "Troubleshooting").
8. If the red LED lights, press the start button. If the tool
does not run, return the tool to the store where the
product was originally purchased or one of our autho-
rised MILWAUKEE® FORCELOGIC™ service centres.
9. If the red and green LED's flash alternately, the tool must
be serviced by one of our authorised MILWAUKEE®
FORCELOGIC™ service centres.