automatically freezes down again to Granita setting viscosity.
To operate the defrost timer proceed as follows (see figure 18).
1 - Set the time of the day by rotating the dial clockwise (arrow
A). Never rotate the timer counterclockwise as this
would damage the internal mechanism. Align the current
time of day with the arrow B on the timer face. This is a 24
hour timer showing both A.M. and P.M.
2 - Program the defrost timer by pushing out on the tabs C
that correspond to the hours desired to defrost. Each tab
represents 15 minutes. A minimum of four to eight hours
are required to defrost frozen beverage (depending on
ambient conditions).
Note: when all the tabs are pushed in the defrost function is
OFF (the machine operates as if it were not equipped with
Defrost Timer).
figure 18