Chamberlain LiftMaster ELITE EL25 User Manual

Telephone entry/access control system
Hide thumbs Also See for LiftMaster ELITE EL25:

Advertisement

EL25 & EL2000
TELEPHONE ENTRY/ACCESS CONTROL SYSTEM
RESIDENTIAL AND COMMERCIAL
TELEPHONE ENTRY SYSTEMS WITH EXPANDED
CAPACITY AND ENHANCED VERSATILITY
Optional modules let you expand the system to fi t your
specifi c needs. The Wiegand output module lets you add
card readers and/or remote keypads. Our RF module
provides convenient access through gates or doors
with Passport™ transmitters. Plus, the system is now
designed to automatically detect the addition and location
of each new plug-in module, making installation and
programming faster and easier than ever before.
These instructions are for general installation and setup.
For more information including detailed wiring specs,
download the guide at www.liftmaster.com.
EL2000
EL25
Wiring
CONNECTING TO THE TELCO LINE
The bypass board allows the unit(s) to be disconnected without interrupting
Disconnect power at the fuse box BEFORE proceeding. The unit
normal telephone operation. If the unit(s) will be used in conjunction with an
MUST be properly grounded and connected in accordance with
alarm system, you must connect the telephone line to the alarm system fi rst.
national and local electrical codes. NOTE: The unit should be on a
If the units are not connected in this order, they will not operate properly.
separate fused line of adequate capacity.
Up to 7 units can share the same phone line. You must program the unit id's
• A static discharge can damage circuit boards
for each unit wired in the series. See Keypad Programming manual.
• NEVER run telco wires and high voltage wires in the same
The bypass board (located inside the property) allows access to the phone in
conduit. The high voltage may interfere with the telco wires,
case the unit(s) fail.
possibly causing the system to malfunction.
NOTE: Installation where fi ber optic phone lines are present may require
additional modifi cations from your telephone provider. Contact your provider
for more information.
• When a unit is in use, the bypass switch must be set to the
operate position.
• To AVOID damaging gas, power or other underground utility
• When a unit is disconnected, the bypass switch must be set to the
lines, contact underground utility locating companies BEFORE
bypass position.
digging more than 18 inches (46 cm) deep.
• Contact the building inspector's offi ce in the municipality where
you plan to install the unit for correct grounding materials and
installation procedures.
STAND ALONE SYSTEM
• Ensure that the system is grounded properly. The units contain
The unit can be a stand alone system that allows communication between
a number of static sensitive components that can be damaged
the unit and a resident's phone. Connect a twisted wire (18-24 AWG) from
by static discharge.
the RES terminal block on the unit's output board, to the resident's phone.
• DO NOT ground the units to a pedestal post (gooseneck) if one
Up to 7 units can share the same phone line. You must program the unit id's
for each unit wired in the series. See Keypad Programming manual.
is used.
Only disable the Telco mode of the unit farthest away from the house. See
GROUND THE UNIT
"Disable Telco Mode" in the Keypad Programming manual.
Install an earth ground rod no further than 12 feet from the unit and
NOTE: Ringer Equivalence Number (REN) of "5" maximum.
use a minimum of 12 gauge wire in most cases. The type and length
of earth ground rods vary by region.
NOTE: Keep ground wire as straight as possible.
ALTERNATIVE GROUNDING SOLUTIONS
CONNECTING TO AN NPBI SYSTEM
The unit may be grounded to a metallic or an existing electrical system
Up to 7 units may be installed. You must program
within 12' of the unit.
the unit id's for each unit wired in the series.
See Keypad Programming manual.
OR
CONNECTING TO A DEDICATED TELCO LINE
Installation where fi ber optic phone lines are present may
require additional modifi cations from your telephone
Green Ground Wire
provider. Contact your provider for more information.
Up to 7 units may be installed. You must program the
unit id's for each unit wired in the series.
See Keypad Programming manual.
12 ft Maximum
Metallic Cold
Water Pipe
CONNECTING TO AN INTERNAL PHONE SYSTEM
Ground Wire
The units can be wired to any analog trunk in an internal home phone
system.
Installation where fi ber optic phone lines are present may require
additional modifi cations from your telephone provider. Contact your
Earth Ground Rod
provider for more information.
Electrical Panel
Up to 7 units may be installed. You must program the unit id's for each
unit wired in the series. See Keypad Programming manual.
Alternative Grounding Solutions
Installation
EL25
EL2000
The EL25 is for surface mount applications only.
The EL2000 is for surface and recessed mount only.
1
1
Unlock the unit and open cover. Carefully lift
Apply pressure to the right-side of the unit. While
mounting plate up then slide out on hinges.
maintaining pressure, turn key clockwise and open
the cover.
Unplug the two main harnesses.
Unplug the two main harnesses.
2
2
(Optional)
Line up notch with screw and push hinge out. Remove
Slide cover out of hinges to remove.
3
3
the mounting plate from the cover.
(Optional)
Bypass Board
Bypass Board
for Unit 1
for Unit 2
Home Phone
Telco Entrance Box
Alarm SystemPosition
Demarcation Point
(Not Provided)
Ring
Ring
Tip
Tip
Tip
Ring
To RES
To TELCO
Unit ID 2
Output Board
Home Phone
Sentex Ovation Unit
Ring
Tip
Telco Entrance Box
Demarcation Point
Ring
Tip
Internal Phone System
Analog Trunk
EL25
Mount to a wall or pedestal.
4
6 in.
3-15/16 in.
10-1/4 in.
PEDESTAL
3-1/16 in.
3 in.
3-1/16 in.
Mounting Holes (4)
5-1/8 in.
for 5/16 in.
1-1/16 in.
Conduit Hole
OPTIONAL
VERTICAL MOUNTING
Rotate the keypad for vertical mounting:
1
Disconnect all plugs from the main
circuit board. Remove board (See
control board connections below).
2
Remove bracket (4 screws).
3
Rotate keypad 90° clockwise. Bracket
notch lines up with ribbon cable on
3
Keypad
the keypad.
J401 KEYPAD
4
Reverse the sequence to reassemble
2
the unit.
Bracket
5
Reconnect all plugs to the control
board.
1
Main Circuit
J402 LED
Board
J402 LED
Lock the unit. Do not pinch wires
5
when closing and locking the unit.
To next unit
(Unit ID 5 then Unit ID 4 etc.)
Output Board
Unit ID 6
For additional
3
units
Ring
1
Tip
4
Use 18-24 AWG
2 twisted pair
Ring
5
2
Tip
6
For additional
units
14-Pin to
Control Board
TERMINAL BLOCK CONNECTIONS
1
Resident - Tip/Ring
2
Telco - Tip/Ring
3
Relay 4, NO, NC, COM
4
Relay 3, NO, NC, COM
Unit ID 2
5
Relay 2, NO, NC, COM
6
Relay 1, NO, NC, COM
To next unit
(Unit ID 3, then Unit ID 4, etc.)
EL2000
Mount to a wall or pedestal. Knock out
4
the desired mounting plugs using punch.
Knockouts for 3/8 in.
Knockouts for 5/16 in.
15 in.
WALL
1-1/2 in.
1/2 in.
1-5/8 in.
2 in.
1-5/8 in. Conduit Hole
12 in.
PEDESTAL
Knockouts
for 5/16 in.
J406 LCD
Knockouts
J201 MIC
for 3/8 in.
J402 SPKR
Turn the key counter-clockwise to
5
the locked position. Close the cover.
Apply pressure to left-side until
you hear a "click" sound. Apply
pressure to right-side of unit until
you hear a "click" sound.
CONNECTING A GATE OPERATOR
Refer to the gate operator manual for proper relay
strike time. Additional opening or exit devices can
be connected to any of the 4 relays.
Normally Open
Common
Use 18-24 AWG
CONNECTING TO A DOOR STRIKE LOCK
The door strike can be connected to any of the 4 relays.
FOR AC POWER: Install a Siemens S10K30 MOV (Metal Oxide Varistor) or equivalent.
FOR DC POWER: Install a 1N4005 diode or equivalent.
DO NOT USE THE UNIT'S POWER SUPPLY FOR THE DOOR STRIKE.
Normally Open
1N4005 diode
or equivalent.
Common
Use 18-22 AWG
AC or DC Power for
Door Strike (Not Provided)
CONNECTING A MAGLOCK
The maglock can be connected to any of the 4 relays.
FOR AC POWER: Install a Siemens S10K30 MOV (Metal Oxide Varistor)
or equivalent
FOR DC POWER: Install a 1N4005 diode or equivalent.
DO NOT USE THE UNIT'S POWER SUPPLY FOR THE MAGLOCK.
Normally Closed
1N4005 diode
or equivalent.
DO NOT overload the
removable terminal
block connectors.
One wire per hole.
Common
Use 18-22 AWG
AC or DC Power for
Door Strike (Not Provided)
9 in.
7 in.
3-1/16 in.
1-15/16 in.
6 in.
WALL
Siemens S10K30 MOV
(Metal Oxide Varistor)
or equivalent.
Siemens S10K30 MOV
(Metal Oxide Varistor)
or equivalent.

Advertisement

loading

Summary of Contents for Chamberlain LiftMaster ELITE EL25

  • Page 1 Installation EL25 & EL2000 TELEPHONE ENTRY/ACCESS CONTROL SYSTEM The EL25 is for surface mount applications only. Unlock the unit and open cover. Carefully lift mounting plate up then slide out on hinges. Unplug the two main harnesses. RESIDENTIAL AND COMMERCIAL TELEPHONE ENTRY SYSTEMS WITH EXPANDED CAPACITY AND ENHANCED VERSATILITY Optional modules let you expand the system to fi...
  • Page 2 Faceplate Gray, No Window 41B1003 41B996 Faceplate Nickel, No Window 41B1004 AS YOUR TELEPHONE WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART NAME • MODEL NUMBER 1-800-528-2806 WWW.LIFTMASTER.COM © 2011, The Chamberlain Group, Inc. All Rights Reserved...

This manual is also suitable for:

Liftmaster elite el2000