Electrical Connection - KitchenAid YKFEG500EBS Installation Instructions Manual

30" (76.2 cm) freestanding
Hide thumbs Also See for YKFEG500EBS:
Table of Contents

Advertisement

Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover from range.
A. Mounting tabs (2 - each side)
B. Terminal block cover
C. Hex-head screws
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Add strain relief.
8

Electrical Connection

A
B
C
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Style 1: Power Supply Cord Strain Relief
Remove the knockout for the power supply cord.
Assemble a UL listed strain relief in the opening.
A. UL listed strain relief
Tighten strain relief screw against the power supply cord.