Mute group 1 (scene memory number 1)
CHECK
CHECK
ON
ON
ON/
ON/
EDIT
EDIT
MUTE
ON
(OFF)
Mute group 3 (scene memory number 3)
CHECK
CHECK
ON
ON
ON/
ON/
EDIT
EDIT
ON
ON
When Mute Group is used
1
2
The mute settings of memory number 1
are recalled
3
CHECK
CHECK
4
ON
ON
ON/
EDIT
5
MUTE
ON
6
7
8
1
2
The mute settings of memory number 3
are added
3
CHECK
CHECK
4
ON
ON
ON/
EDIT
5
MUTE
ON
6
7
8
Adding/defeating mute groups
1. Store the channel or bus mute settings that you
wish to use as a mute group in a memory num-
ber 1–8.
2. In utility mode, select the oP (recall operation)
item, and switch the display to "
details refer to page 34.)
3. Either press and hold the UTILITY switch for one
second or more, or press the UTILITY switch
repeatedly to return to normal mode.
Even if the Utility mode item oP is set to "
can edit scenes 1–8 either by using the 0–9/ENTER
buttons to specify the scene number or by entering
check mode.
4. Press a DIRECT RECALL 1–8 switch.
The corresponding mute group will become active,
and the channels or buses which are turned off
(muted) in that scene will be muted.
5. As desired, press other DIRECT RECALL 1–8
switches.
Mute groups will be added, and channels or buses
which are turned off (muted) on those scenes will be
muted.
CHECK
CHECK
CHECK
ON
ON
ON
ON/
ON/
ON/
EDIT
EDIT
EDIT
ON
MUTE
ON
(OFF)
CHECK
CHECK
CHECK
ON
ON
ON
ON/
ON/
ON/
EDIT
EDIT
EDIT
ON
MUTE
MUTE
(OFF)
(OFF)
CHECK
CHECK
CHECK
ON
ON
ON
ON/
ON/
ON/
ON/
EDIT
EDIT
EDIT
EDIT
ON
MUTE
ON
CHECK
CHECK
CHECK
ON
ON
ON
ON/
ON/
ON/
ON/
EDIT
EDIT
EDIT
EDIT
ON
MUTE
MUTE
." (For
," you
About the Scene Memory function
6. If you wish to defeat a mute group, press the cor-
responding DIRECT RECALL 1–8 switch.
The mute group will be canceled.
Note:
• The mute settings used in a mute group are the
same as the on/off settings of the scenes stored
in memory numbers 1–8.
• Even while using mute groups, you can use the
/
switches or 0–9/ENTER buttons to recall
memory numbers 9–128. However in this case,
the currently-muted channels or buses will not
change until you defeat the applicable mute
groups.
• If you use the 0–9/ENTER buttons to recall
memory number 129 (all on) or 130 (all off),
the mute group settings of the DIRECT
RECALL 1–8 switches will be defeated.

About the local control circuit

If an error occurs in the system of the M3000, the on/
off control of each input channel and bus will auto-
matically switch from the scene memory circuit to the
local control circuit, allowing you to operate the
M3000 like a conventional analog mixer. In this case,
the ON/EDIT switch of each input channel or mix
channel will function like a conventional ON/OFF
(mute) switch. However, the MEMORY display will
go dark, and the switches for the Scene Memory func-
tionality cannot be operated.
Note: If the cause of the system error lies in the
power supply, it may not be possible to use the local
control circuit either.