Problem: Water leaking from faucet airgap hole.
Cause: Drain side of faucet airgap (3/8" black tub-
ing) plugged, restricted or incorrectly con-
nected to drain point.
Problem: Faucet LED indicator light does not function after battery change.
Cause: Battery dead.
Cause: Battery installed incorrectly.
Problem: Water leaks at push connect fittings
Cause: Tubing not cut square.
Cause: Tubing not pushed in all the way.
Cause: Tubing nicked.
Cause: Outer tubing surface finish not smooth. Correction:
Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223

Troubleshooting

Correction:
Inspect and eliminate restriction or plug. Refer to installation instruc-
tions for proper drain connection. See Page 8 and 9.
Correction:
Replace with new battery. See Page 21.
Correction:
Install battery correctly. See page 13 or 16.
Correction:
Cut tubing square. See Page 14 and 15.
Correction:
Push tubing in all the way. See page 14 and 15.
Correction:
Remove tube from connection. Remove nicked portion by cutting
tube to shorter length. Re-insert in connection. See page 14 and 15.
Remove tube from connection. Remove problem area by cutting
tube to shorter length. Re-insert in connection. See Page 14 and
15.