Natural Gas Conversion - KitchenAid KCGC506JSS Installation Instructions Manual

Hide thumbs Also See for KCGC506JSS:
Table of Contents

Advertisement

Available languages

Available languages

Natural Gas Conversion

1. Turn the manual shut‑off valve to the closed position.
A
A. To cooktop
B. Shut-off valve (closed position)
C. Gas supply line
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator from Propane to
Natural Gas
1. Remove the gas pressure regulator cap by using a large flat
blade screwdriver, turning the regulator cap counterclockwise.
When the cap is removed, do not lose the metal seal.
NOTE: Do not remove the spring beneath the cap.
2. Remove spring retainer from the cap by turning the spring
retainer counterclockwise. Locate the "LP" and "NAT"
position on the spring retainer. Turn over the spring retainer
so the "NAT" arrow is pointing toward the cap.
A
B
C
A. Access cap
B. Metal seal
C. Gas pressure regulator
16
B
C
LP
NAT
D
E
LP
NAT
D. Spring retainer in LP
position
E. Spring retainer in NAT
position
3. Tighten the gas pressure regulator cap by using a large flat‑
blade screwdriver, turning the regulator cap clockwise.
4. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Natural Gas:
Minimum pressure: 5" (12.7 cm) WCP
Maximum pressure: 14" (35.6 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 1"
(2.5 cm) water column pressure above the manifold pressure
shown on the model/serial/rating plate.
Line pressure testing above 1/2 psi (3.5 kPa) gauge (14"
[35.6 cm] WCP)
The cooktop and its individual shut‑off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psi (3.5 kPa).
Line pressure testing at 1/2 psi (3.5 kPa) gauge (14"
[35.6 cm] WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shut‑off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
To Convert Surface Burners from Propane to
Natural Gas
1. If the burner grates are installed, remove them.
2. Remove burner cap.
3. Remove the burner base by first removing (2) T‑20 screws.
A
B
C
4. Apply masking tape to the end of a 1/4" (7 mm) nut driver
to help hold the gas orifice spud in the nut driver while
changing it. Insert nut driver into the gas opening and press
down onto the gas orifice spud and remove by turning the
gas orifice spud counterclockwise and lifting out. Set gas
orifice spud aside.
5. Replace with correct Natural gas orifice spud. See the
"Natural Gas Orifice Spud/Hood Chart."
Burner
A. Burner cap
B. Screws
C. Burner base

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kcgc558jssKcgc500jss

Table of Contents